Operating Parameters
Ambient water temperature
Maximum temperature
30°C
Hot water temperature
Maximum inlet temperature
80°C
BS 6700 recommends hot water storage temperature should not
exceed 65°C.
Hot water should be set in the range of 60 to 65°C to meet
requirements of the shower unit.
Operating pressure
Minimum maintained pressure
0.0075 bar
or
75mm
head of water.
Maximum maintained pressure
0.5 bar
.
Maximum static pressure
1bar
or
10m
head of water.
Maximum pressure loss ratio
10:1
.
Standards
The Essentials Thermostatic Power Shower has been designed to
comply with the requirements of UK Water Regulations/Bye-laws
(Scotland).
The Essentials Thermostatic Power Shower complies with all the
relevant EC directives.