TROUBLE SHOOTING GUIDE  

 

                       E-5 

1. No power, logs do not glow.

1a. Check that unit is plugged into a 

standard 120 volt outlet.

1b. Press POWER switch several times,

make sure power is set at “ON” position.

2a. Open the rear cover, then check for any 

broken light bulb or loose light bulb.

2b. Loosen and remove the burnt 

out bulb and replace with new bulb.
3a. Open the rear cover, then check if 

spinner motor was working. If not, 

call customer service.

2. POWER switch light up, 

but no flame effect.

3. Logs Glow, flame effect does 

not work.

PROBLEM

SOLUTION

4. Flame effect operates, but 

heater does not blow warm air.

5. Heater doesn’t work, but 

POWER and HEATER switches 

are in the “ON” position.

5a. Turn all switches to the “OFF” position 

and unplug the unit from the wall outlet 

for 5 minutes. After 5 minutes plug the 

unit back into wall outlet, and operate as 

normal.

4a. Check the HEATER switch is in“ON” 

position. POWER switch should light up. 

6. 

Alarm light flash and  

heater function does not 

work.

6a. The heater is getting excessively hot, 

immediately turn the heater off, 

unplug 

the unit and inspect for any 

 and 

inspect for any objects on or 

adjacent to the heater that may 

cause high temperatures.

Summary of Contents for SP18-1705-BU

Page 1: ...OWNER S MANUAL Date of purchase _____ _____ _____ CARTER FIREPLACE Product code 0 08487459 3 UPC code 817266010243 ...

Page 2: ... unit and make sure there is no damage If you have any problem with assembling the unit with how the various functions work or with damage or missing parts Please call 1 203 440 9911 9 00AM 5 00PM EST or email customerservice prokonian com immediately for service before return the unit to the store where it was purchased ...

Page 3: ... STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE E 1 ELECTRIC FIREPLACE HEATER Thank you and congratulations on your purchase of a Prokonian fireplace Please read the installation operating instructions before using this appliance ATTENTION FIND A LOCATION FOR THE FIREPLACE HEATER THAT IS PROTECTED FROM DIRECT SUNLIGHT Prokonian Inc 63 Gol...

Page 4: ...appliance when not in use 4 Do not operate any heater with a damaged cord or plug or after the heater malfunctions or if it has been dropped or damaged in any manner Disconnect power at service panel and have heater inspected by a reputable electrician before reusing 5 Any repairs to this fireplace should be carried out by a qualified service person 6 Under no circumstances should this fireplace be m...

Page 5: ...o not use it in areas where gasoline paint or flammable vapors or liquids are used or stored This fireplace should not be used as a drying rack for clothing Christmas stockings or decorations should not be hung in the area of it 17 Use this appliance only as described in the manual Any 18 other use not recommended by the manufacturer may cause fire electric shock or injury to persons Always plug heat...

Page 6: ...lts The cord has a plug as shown at A An adapter as shown at C is available for connecting three blade grounding type plugs to two slot receptacles The green grounding plug extending from the adapter must be connected To a permanent ground such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available 21 SAVE THESE INSTRUCTIONS ...

Page 7: ...gs Glow flame effect does not work PROBLEM SOLUTION 4 Flame effect operates but heater does not blow warm air 5 Heater doesn t work but POWER and HEATER switches are in the ON position 5a Turn all switches to the OFF position and unplug the unit from the wall outlet for 5 minutes After 5 minutes plug the unit back into wall outlet and operate as normal 4a Check the HEATER switch is in ON position POW...

Page 8: ...ion to avid the use of an extension cord If an extension cord must be used it must be a minimum 14 AWG three wires with grounding type plug connector and rated not less than 1875 watts The cord shall not be more than 20 feet 6m in length Keep electrical cord drapery furniture and other combustibles at least 3 feet 0 9m from the front of the heater and away from the sides Clean the metal trim using...

Page 9: ...nscrew the 6 screw then remove the back plate figure 1 and 2 Pull the bulb fixing spring to loosen the bulb and rotate the bulb Then remove the bulb Replace the bulb and use the fixing spring to fixing the bulb Screw the back plate and enjoy your fireplace NOTE Light bulb may become loose during shipping If the flame effect is dim or does not work please check that light bulb is finger tight in socket See...

Page 10: ...First press the main power switch to off Then remove the electrical plug from the wall outlet This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they ve been given supervision or instruction concerning use of the appliance by a person responsible for their safety The adult should superv...

Page 11: ...Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes If repairing or replacing any electrical component or wiring the original wire routing color coding and securing locations must be followed WARNING Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the ri...

Page 12: ...part s found to be defective in material or workmanship provided that such part s have been subjected to normal conditions of use and service after sad defect is confirmed by the Company s inspection This warranty does not cover the light bulb included with the Prokonian Electric Fireplace The Company may at its discretion fully discharge all obligations with respect to this warranty by refunding t...

Page 13: ...on of this product This warranty gives you specific legal rights and you may also have other rights which vary from state to state 9 10 11 IF WARRANTY SERVICE IS NEEDED This warranty is void if a The fireplace is subjected to prolonged periods of dampness or condensation b Any unauthorized alteration willful abuse accident or misuse of the product c You do not have the original receipt of purchase C...

Page 14: ...INA for Kmart Corporation Hoffman Estates IL 60179 SHOP kmart com For questions or comments about the product Email Customerservice Prokonian com or Call toll free 1 203 440 9911 Please refer to part code when reordering ...

Reviews: