MANTEL LOCATION
ELECTRICAL SPECIFICATIONS
SPECIFICATIONS
Voltage: 120 VAC, 60HZ
Amps: 11.7 amps
Watts: 1400 Watts
CLEARANCE TO COMBUSTIBLES
CLEANING TRIM
E-6
When choosing a location for your
new fireplace, ensure that the
general instructions are followed.
Also for best effect, install the
fireplace out of direct sunlight.
A 15 AMP, 120 Volt, 60 Hz circuit
with a properly grounded outlet is
required. Preferably, the fireplace
will be on a dedicated circuit as
other appliances on the same circuit
may cause the circuit breaker to trip
or the fuse to blow when the heater
is in operation. The unit comes
standard with 6 fee (1.8m) three
wire cord , exiting from the rear of
the fireplace. Plan the installation to
avid the use of an extension cord. If
an extension cord must be used, it
must be a minimum 14 AWG; three
wires with grounding type plug
connector and rated not less than
1875 watts. The cord shall not be
more than 20 feet (6m) in length.
Keep electrical cord, drapery, furniture
and other combustibles at least 3 feet
(0.9m) from the front of the heater and
away from the sides.
Clean the metal trim using a soft
cloth, slightly dampened with citrus
oil based product and buff with a
clean soft cloth. DO NOT use brass
polish or household cleaners as these
products will damage the metal trim.
Citrus oil based products can be
obtained at supermarkets or
hardware stores.
ELECTRICAL CONNECTION
Cold climate installation
Recommendation:
When installing this unit against a
non-insulated exterior wall or chase, it is
mandatory that the outer walls be
insulated to conform to applicable
insulation codes.