background image

QUICK PROGRAMMING GUIDE 

Page 23 

ADVANCED PROGRAMMING 

ASSIGN NEW PIN  
(INST) 

 

 (PIN) 

 

 (PIN) 

 

DISABLE PIN 
REQUEST 
(INST) 

 

RESTORE PIN 
REQUEST 
(INST) 

  

TEST OF ALARMS 
(INST) 

 

 emergency-call button 

 battery technology alarm 

 periodic automatic test call 

 no external power supply alarm 

 auxiliary alarm 

Summary of Contents for Helpy GSM-RM

Page 1: ...15 09 2017 Alarm system for elevators QUICK GUIDE...

Page 2: ...for define the behaviour of output AR C Built in backup battery connector D Internal power supply connector E Reset pushbutton F Alarm pushbutton G Built in loudspeaker connector H Serial port for PC...

Page 3: ...RM LED signalling alarm periodical test call yellow LED signalling GSM signal strength green not used LED signalling power supply status blue LED GSM SATELLITE red LED signalling GSM status green LED...

Page 4: ...SSIVE HANDSFREE TERMINAL OR A SINGLE MICROPHONE 13 MIC3 INPUT FOR CONNECTING THE MICROPHONE OF A PASSIVE HANDSFREE TERMINAL OR A SINGLE MICROPHONE 14 NEGATIVE POLE 15 TEL LOCAL TELEPHONE 16 RL1 RELAY...

Page 5: ...until it unlocks and lift it Carefully slide the SIM Card into its housing cover Lower the SIM Card housing cover and push it as indicated by the arrow LOCK until it locks in place Close the GSM satel...

Page 6: ...ree terminal can be installed at max 6 m distance from HelpyGSM RM or from another active handsfree terminal by using a shielded cable Note in case of connection of active handsfree terminals the type...

Page 7: ...FLOOR 3 Active handsfree VVX ALZ LANDING FLOOR 4 Passive handsfree terminal combined to the active handsfree terminal positioned in the landing floor 3 ALZ PROGRAMMING CODES TYPE OF INSTALLATION TO BE...

Page 8: ...pushbutton It is possible to connect inside the elevator car voltage free contact pushbuttons or powered pushbuttons Connect following one of the diagrams shown below the car pushbutton Voltage free c...

Page 9: ...STALLING Page 9 Other pushbuttons It is possible to use for the pit the car top or the landing floors voltage free contact pushbuttons NO Connect following the diagram shown below the other pushbutton...

Page 10: ...switches on after pressing the emergency button to indicate the beginning of the alarm procedure and stays steady light until the end The RECEIVED ALARM INDICATOR LIGHT green switches on when the alar...

Page 11: ...Y INPUT Connect the external contact normally open to ALZ and terminals Note the ALZ input must be programmed as auxiliary input by setting parameter 55 CONNECTING THE RELAY Connect the output RL1 nor...

Page 12: ...Page 12 INSTALLING WIRING DIAGRAM EXAMPLE 1...

Page 13: ...INSTALLING Page 13 WIRING DIAGRAM EXAMPLE 2...

Page 14: ...seconds as shown in the paragraph LED signalling GSM status on page 27 If the GSM status LED flashes quicker and stays lit for a longer time see on page 27 the HelpyGSM RM has not properly registered...

Page 15: ...handset and dial Make an external call to check the telephone line presence dial and after the Correct message digit the telephone number to make a test call 2 TESTING THE ALARM PROCEDURE Press the em...

Page 16: ...larm call By pressing shortly you get the same result as lifting the handset of the local telephone and entering Password Pressing longer 10 seconds Allows to reset the device By pressing longer the H...

Page 17: ...ming BASIC PROGRAMMING ACCESS TO PROGRAMMING INSTALLER or OPERATOR PASSWORD factory setting EXITING THE PROGRAMMING INSTALLER or OPERATOR PASSWORD factory setting TELEPHONE NUMBERS INST position from...

Page 18: ...25s LISTEN TO THE MESSAGES INST OPER identification message listen courtesy message TYPE OF INSTALLATION INST Number of active handsfree terminals only the built in active handsfree terminal built in...

Page 19: ...enabled Manually perform a test call PROTOCOLS IDENTIFICATION CODE INST Esse ti identification code P100 HANDSFREE TERMINALS VOLUME INST OPER built in active handsfree terminal loudspeaker from 1 to...

Page 20: ...ATOR PASSWORD INST old new new EMERGENCY CALL BUTTONS DELAY INST seconds from 2 to 9 CAR EMERGENCY CALL BUTTON ALC NORMALLY CLOSED OPEN INST normally closed normally open NO EXTERNAL POWER SUPPLY ALAR...

Page 21: ...its factory default 5 HANDSFREE ACTIVATION CODE INST from 1 to 3 digits factory default 0 END ALARM CODE INST from 1 to 3 digits factory default 9 EXCLUSION CODE INST from 1 to 3 digits factory defaul...

Page 22: ...direct connection with the car CONNECTION DURATION AFTER AUTOMATIC RESPONSE INST minutes from 1 to 9 RELAY SETTING INST same behaviour as output AI same behaviour as output AR active for external powe...

Page 23: ...CED PROGRAMMING ASSIGN NEW PIN INST PIN PIN DISABLE PIN REQUEST INST RESTORE PIN REQUEST INST TEST OF ALARMS INST emergency call button battery technology alarm periodic automatic test call no externa...

Page 24: ...e programming codes to be performed The message format must be as follows Et hg xxx c c c c Where Et hg is the start of the programming string xxx is the password string default installer password xxx...

Page 25: ...CTIVATE ALL EXTERNAL CALLS TELEPHONE NUMBER DOOR OPENER RELAY HEAR THE GSM SIGNAL LEVEL Use remotely with HelpyGSM RM at rest Call HelpyGSM RM and wait for a response After listening to the elevator i...

Page 26: ...call alarm Emergency call alarm suspended Other alarms Test call LED signalling GSM signal strength green No signal Low signal level Medium signal level Good signal level High signal level Note the gr...

Page 27: ...ply is connected and the battery has max capacity charge The external power supply is connected and the battery has good capacity charge The external power supply is connected and the battery has medi...

Page 28: ...dedicated location SIM card locked by PIN code Enter the PIN using the code 282 SIM card expired or damaged Check the SIM card operation on your mobile phone SIM card not supported e g UMTS Use a GSM...

Page 29: ...NOTE Page 29 NOTE...

Page 30: ...Page 30 NOTE...

Page 31: ...NOTE Page 31...

Page 32: ...HelpyGSM RM edition 15 09 2017 Esse ti s r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 071 7506066 Fax 39 071 7506057 www esse ti it e mail support esse ti it...