27
ess TrG Owner’s Manual
Troubleshooting guide
when you encounter the problems listed below, use the suggested trouble-shooting methods. If you can-
not solve the problem or have a problem with the spray Gun that is not addressed in this manual, contact
ess at (706) 769-0025.
air pressure of spray
· Inadequate compressor
· Make sure that the air compressor is rated for the required
appears low
air flow. see page 6 for air flow requirements.
· Make sure that the air compressor is supplying the correct
air pressure. see page 6 for air pressure requirements.
· spray gun On/Off valve is closed
· Make sure that the ball valve is completely open.
· adjust the inlet air pressure regulator to the correct
pressure
setting.
· Fittings are loose
· Make sure that all quick connect sockets are properly
seated.
· bowl filter is clogged or dirty
· empty the liquid inlet bowl filter of water.
· liquid fittings are loose
· Make sure the liquid Filter assembly is installed correctly.;
· air fittings are loose
· Make sure that the air Filter is installed correctly.
or damaged
Inspect for loose hoses or failed air lines –
spray fittings with soapy water – tighten ones that bubble
replace
if
necessary
Clogged liquid Filter
· Clean the liquid Filter assembly on spray gun
(see
the
Liquid Filter Assembly
section of this manual)
· Clogged air Filter
· Clean the air Filter
(see
The
Air Filter Assembly
section of this manual)
· Dirty Trigger
· Clean the Trigger
(see
the
To Clean the Trigger
section of this manual)
no spray from nozzle or
· Debris in the nozzle
· Clean nozzle according to instructions
the spray from nozzle is
erratic or spits
· spray is freezing due to
·Make sure that water temperature is at least 50° (10°C)
evaporative
cooling
· Incorrect tank pressure
Make sure that the tank pressure regulator is set at 12-15 PsI.
Make
sure
the
tank
lid
is
sealed.
· liquid filters are clogged
· Clean the liquid Filter assembly
(see
the
Liquid Filter Assembly
section of this manual)
· low liquid level in the tank
· refill tank
· loose liquid or air fitting
· Inspect hose quick connects at case and at spray gun
leader. Make sure that all liquid fittings and air fittings are
properly
seated.
· Dirty Trigger
· Clean the Trigger
(see
the
To Clean the Trigger
section of this manual)
· Overtightened nozzle cover
· loosen cover. It should only be finger-tight
· suspect tank pressure regulator
· Verify that the tank pressure regulator functions properly.
Follow
the
procedure
on
page
15:
· suspect air pressure regulator
· Verify that the air pressure regulator functions properly.
Follow
the
procedure
on
page
14:
Charging indicator (leD)
· batteries are exhausted
recharge batteries
blinks or goes is out
If problem persists, replace battery pack
during operation
· Dirty nozzle
· Clean nozzle according to instructions
Symptom
Possible Problem(s)
Corrective Action
Summary of Contents for TRG-5
Page 1: ...Owner s Manual TRG 5 Owner s Manual TRG 5 Electrostatic Spraying Systems...
Page 4: ...ii ESS TRG OWNER S MANUAL Notes...
Page 6: ...iv ESS TRG OWNER S MANUAL Notes...
Page 16: ...10 ESS TRG OWNER S MANUAL Notes...
Page 34: ...28 ESS TRG OWNER S MANUAL Spray Gun Service Parts See note next page...
Page 36: ...30 ESS TRG OWNER S MANUAL...
Page 38: ...32 ESS TRG OWNER S MANUAL...