8
ess TrG Owner’s Manual
To set the tank pressure:
Turn on the air from the
pressurized air source. set the
incoming air pressure accord-
ing to the instructions on the
previous page.
locate the tank pressure gauge
(liquid-filled gauge marked
1
–
30 PsI). Pull the adjustment
knob’s black plastic cover to
unlock it. Turn left (counter-
clockwise) to decrease pres-
sure; turn right (clockwise)
to increase pressure. set the
pressure between 12 to 15 PsI.
Push the black plastic cover in
to lock the new setting.
Supply air line drier
ess recommends that growers install dryers in their air lines to mini-
mize the amount of water condensation that is sprayed through the air
line of the TrG-5. air compressors produce warm, moist air which con-
densates in air delivery lines during pumping. If allowed to travel into
a sprayer, this moisture can corrode or freeze its air lines or regulators.
a simple air dryer installed in the hose air lines can prolong the life of
spraying equipment. Typically, an air dryer is a separator or drain with
a plug or valve that is offset from the line to trap water build-up before
it leaves the air line through connectors. air lines should be drained
monthly if they are used frequently.
Steps for operation
1. Connect external air supply to the air inlet hose
2. Disconnect tank quick connects and open tank.
3. Prepare tank mix.
4. Close tank and reconnect all quick connects.
5. Disconnect spray gun quick connect sockets from the
frame quick connect plugs; connect spray gun quick
connect sockets to handgun plugs.
6. Turn on air at external supply.
7. set unit air pressure as described on the previous page.
8. set tank pressure regulator to 12-15 PsI.
9. aim spray gun at spray target and engage trigger;
lock trigger if desired. note: It takes about 2 minutes for
liquid to spray regularly without air bubbles.
10. apply spray.
After spraying:
1. Disengage trigger when spray application is complete.
2. Turn ball valve off.
3. Disconnect tank quick connects and open tank; clean tank
interior and exterior; fill tank with 2 gallons of clean, soapy
water; close tank and reconnect tank.
4. unplug spray gun quick connect sockets from the spray
gun quick connect plugs.
5. Disassemble liquid filter assembly.
6. Plug spray gun quick connect plug (which is still threaded
in the 1/8” nPT body) into spray gun liquid quick connect
socket. 1.
7. Turn ball valve on.
8. unplug spray gun liquid quick connect plug from spray gun
liquid quick connect socket to stop flow of liquid.
9. Clean liquid filter assembly.
10. reassemble liquid filter assembly.
11. reconnect spray gun quick connects.
Air line drier
Summary of Contents for TRG-5
Page 1: ...Owner s Manual TRG 5 Owner s Manual TRG 5 Electrostatic Spraying Systems...
Page 4: ...ii ESS TRG OWNER S MANUAL Notes...
Page 6: ...iv ESS TRG OWNER S MANUAL Notes...
Page 16: ...10 ESS TRG OWNER S MANUAL Notes...
Page 34: ...28 ESS TRG OWNER S MANUAL Spray Gun Service Parts See note next page...
Page 36: ...30 ESS TRG OWNER S MANUAL...
Page 38: ...32 ESS TRG OWNER S MANUAL...