IPS Belt Cleaner
10
19/11/2021
Figure 2b
– Installation on angled belts
Step 2 Mark-Out Chute Cut-outs
Using the previously marked line as the centre line, mark the chute cut-out and bolt
hole locations as shown in figure 3 below. Repeat on both sides of chute, ensuring
that the cut-outs are accurately aligned with each other.
Note
: If replacing a 20-Ten series cleaner with the IPS cleaner, mount hole and cut-
out configuration is exactly the same.
Figure 3
– Chute Cut-out for all Models
Verify Cleaner Position before Proceeding
If not already done, disassemble the cleaner mount / tensioner assemblies from the
cleaner mainframe. To do this, simply remove the retaining pin in the operator side
mount, and slide the blade cartridge from the mainframe. Then remove the retaining
pin in the far side mount to remove the mainframe.