background image

10 

 

 

 

S

AFETY INFORMATION

 

 

Operate the FALCON controller always in dry environment and within the device limits stated in this 

guide. Never expose the device to excessive heat or cold outside the working area. 

 

Provide sufficient airflow to prevent controller overheating. 

 

Never exceed the maximum allowed operating voltage of the controller/motor. 

 

Do not increase the cable length between the controller and motor. In case you need to lengthen the 

wires between the controller and battery to more than 40cm (in total), solder some high capacity low-

ESR capacitors (220-470uF) every 30cm in parallel to the power wires. 

 

Always  use  high  quality  connectors  in  good  condition.  Replace  them  if  any  visible  sign  of  wearing 

appears. 

 

Always remove the propeller prior to making any changes in drive setup. 

 

Never disconnect the ESC from the battery while the motor is spinning. 

 

Do not remove the  cover and heat sink from the device and do not try to implement any changes or 

modifications. This can lead to a total destruction and to the denial of any warranty claims. 

 

Always  check  the  polarity  of  the  connection.  Never  inverse  the  polarity 

  this  could  lead  to  total 

destruction. 

 

 

Summary of Contents for FALCON-120

Page 1: ...EN FR IT FALCON 80 FALCON 120 FALCON 130 FALCON 220 Dimensions 57x35x28mm 58x53x24mm 58x53x28mm 81x63x36mm Weight incl cables 60g 110g 110g 270g Continuous current 80A 120A 130A 220A Peak current 120A...

Page 2: ...configured acceleration time is always applied when accelerating This is a default mode for major use Fast mode the preconfigured acceleration is applied only when spinning up from zero revolutions Af...

Page 3: ...econditions large outrunner with more than 20 poles heavy propeller large current peaks We also recommend increasing timing to more than 20 High speed use this mode if your power setup exceeds 250 000...

Page 4: ...er This sensor T125 ID might be used as a standalone telemetry sensor with Duplex Hott S Bus2 telemetry support Alternatively the sensor can be directly connected to the Input port A of the controller...

Page 5: ...d LED continuously flashes Available status codes Low voltage UL The battery voltage got below the threshold specified in the battery protection menu and the controller either reduced the maximum powe...

Page 6: ...tle input The FALCON 220 uses galvanic separation for all signal cables FALCON 80 and FALCON 120 130 schematic FALCON 220 schematic FAN CONTROL The FALCON 220 contains a driven output for the external...

Page 7: ...e compared to the maximum battery voltage from the previous run This means that each time you connect a fully charged battery of the same chemistry and number of cells the capacity will be cleared Man...

Page 8: ...total energy is limited F5B F5D 9 Temperature C 10 External temperature C if the motor identification chip is connected the ESC forwards motor temperature in its own telemetry 11 Motor status 0 Initi...

Page 9: ...nnect the Telemetry cable red connector to the Prog SRXL2 receiver port The controller normally delivers only numerical telemetry The textual menu TextGen is available only after a special procedure i...

Page 10: ...ttery to more than 40cm in total solder some high capacity low ESR capacitors 220 470uF every 30cm in parallel to the power wires Always use high quality connectors in good condition Replace them if a...

Page 11: ...y port The controller will be automatically detected 4 Select the correct BIN file and press the Update button Note The FALCON 80 and FALCON 120 130 do not require connecting the flight pack prior to...

Page 12: ...12...

Reviews: