eSpring Water Purifier Owner'S Manual Download Page 5

3

Fig. 13

Fig. 10

Fig. 14

Fig. 15A

Fig. 15B

Fig. 16

3

4

" (

)

5

8

" (

)

Fig. 17

BELOW COUNTER INSTALLATION  

PREPARATION FOR THE FAUCET 

OR DISPENSING DEVICE

This installation uses a separate, counter-
mounted 

eSpring

®

 Faucet or any NON-

eSpring

 single line faucet or dispensing 

device. With the 

eSpring

 Water Purifier 

below the counter, these installations allow 
maximum use of counter space, with no 
visible tubing. 

Cold water plumbing must be modified to pro-
vide a 3/8” (9.5 mm) Outer Diameter (O.D.) 
x ¼” (6.4 mm) Inner Diameter (I.D.) tubing 
(plastic or metal) for connection to an auxil-
iary  faucet or dispensing device (Fig. 17).

NOTE: You will need an electrical outlet to plug 
in the Power Adapter. If you need to install a new outlet, it must be installed by a 
licensed or certified electrician according to Federal, Provincial, State, Municipal 
and local laws. This outlet must be powered continuously for the Water Purifier to 
function properly. In case of a power outage, see p. 8.

RECOMMENDATIONS

1.  

Hire a plumber if you do not feel comfortable modifying the plumbing and 
installing the faucet.

2.  

Determine

 type and size tubing or piping needed between the cold water 

supply line and the kitchen faucet. 

Take

 a digital picture of your cold water 

supply plumbing to use as a guide in the hardware store to purchase the 
appropriate parts for installation.

3.   Install a tee in cold water supply and a separate shut-off valve to the tee 

before connection of an Auxiliary Faucet or dispensing device. This will allow  
for rinsing and cleaning of the Water Purifier during cartridge changes.

 

a.   All fittings and valves must be approved for use in pressurized drinking 

water applications.

 

b.   Purchase plastic ferrules when connecting plastic tubes to metal 

compression fittings (which come with metal ferrules for connection to 
metal pipe).

4. 

 Select

 a location for the faucet or dispensing device. There may already be 

an extra, capped hole in your sink’s ledge for a sprayer, soap dispenser or 
extra faucet that can be used for mounting the faucet. If you are removing 
the connected sprayer, it will need to be sealed properly. (See local plumb-
ing store for assistance.)

 

 a.   For 

eSpring

 Faucet: If a new hole is needed, it must be between 1¼” 

(32mm) and 1½” (38mm) in diameter, less than 3 15/16” (100mm) 
from the sink basin and at least 1¼” (32mm) from the wall. Before 
drilling, make sure there is sufficient clearance below the sink or coun-
tertop to accommodate the faucet and allow connections to be made 
to the 

eSpring

 Water Purifier.

 

b.   For  NON-

eSpring

 faucet or dispensing device: Follow manufacturer’s 

use instructions.

NOTE: For solid countertops, it is recommended to use a very sharp bi-blade hole 
saw and start by making a pilot hole. If you have a porcelain/ceramic sink or a tile 
countertop, it is recommended to seek professional assistance for proper drilling.

WARNING:

 Due to the possibility of shock or electrocution, use extreme care 

when operating an electric power drill or other power tools around the sink. 
Avoid contact with water or moisture at all times.

Continue With Faucet Installation

•  Below Counter 

eSpring

 Auxiliary Faucet, p. 4. 

•  Below Counter NON-

eSpring

 Faucet or Dispensing Device, p. 5.

4. 

 Lay

 each tube from the Diverter on the diagram. Use a pen to 

mark

 a line 

across them at the arrows. 

Push

 tubing supports into their respective 

tubes, until they are flush with the end of the tubes (Fig. 13).

5. 

 Insert

 each tube into the proper locations  

on the Bracket until you meet the marks 
or the marks disappear (Fig. 14).

NOTE: You will feel resistance before the tube 
is fully installed.

6.   The Diverter controls the flow of 

water according to the position of  
the pin. 

 

a)   Pin 

pulled out

 - Treated water 

(Fig. 15A).

 

b)   Pin 

pushed in

 - Untreated water 

(Fig. 15B).

7.  

Turn on

 cold water faucet and 

pull 

out

 the Diverter pin.

NOTE: It will take a short time for water 
to saturate the Cartridge and flow from 
the Diverter. Flush for a minimum of 5 
U.S. gallons (20 liters) (approximately 
5-15 minutes) to remove air pockets and 
carbon dust. If water is not clear, see Troubleshotting, p. 8.

8. 

 Check

 for any signs of leakage at the 

Diverter and at all tubing connections  
(Fig 16). If there is leaking or 
bubbling, refer to Trouble-
shooting, p. 7.

9.  

Turn off 

the water and

 push  

in 

the pin, after each use.

NOTE: During use periodically 
check system for leaks.

10.   Skip to COMPLETING THE INSTALLATION, p. 10.

Residents of Massachusetts, please adhere to the State of Massachusetts 

Plumbing Codes. Use a licensed plumber for installation.

1035793_eng.indd   3

6/10/14   4:42 PM

Summary of Contents for Water Purifier

Page 1: ...ct may be covered by one or more of the following U S patents 5 529 689 5 573 666 5 738 780 6 368 504 6 436 299 6 514 420 6 673 250 6 806 649 6 825 620 6 831 417 6 917 163 6 984 320 7 153 178 7 170 20...

Page 2: ...e Installation 11 0720 Refer to the exploded view of the Water Purifier to the right for assistance with part names INSTALLATION AND MAINTENANCE Before beginning installation please review the owner s...

Page 3: ...ptional purity consult your healthcare provider before using IMPORTANT NOTES The eSpring Water Purifier is designed for use only with cold bacteriologically suitable potable water 1 System tested and...

Page 4: ...adapter with inter nal threads and washer to the end of your faucet Fig 4 c If the threads on your faucet are internal attach the appropriate adapter with external threads to the end of your faucet F...

Page 5: ...Faucet If a new hole is needed it must be between 1 32mm and 1 38mm in diameter less than 3 15 16 100mm from the sink basin and at least 1 32mm from the wall Before drilling make sure there is suffic...

Page 6: ...ed Refer to Service Components List p 11 4 Remove the Top Shroud from the Water Purifier Remove the Electronic Module Fig 22 5 Insert the GREEN and BLUE tubes at tached to the eSpring Auxiliary Faucet...

Page 7: ...supply and the eSpring Water Purifier 7 Insert the RED tube from the Pres sure Regulator Assembly into the large port on the Bracket Insert the end of the BLUE tube marked at 5 8 15 mm into the small...

Page 8: ...ted Red Phone icon On Red Need replacement Cartridge Under 10 Cartridge life remaining Blue Blue Blue Last segment flashing Once at flow start Off Order replacement Cartridge End of Cartridge life Blu...

Page 9: ...too short contact Customer Service to order additional tubing and union connector Tubing damaged on surface Tubing not inserted far enough Remove tubing p 9 Fig 32 Mark tubing p 5 Fig 25 Install tubi...

Page 10: ...d put 5 ml or a teaspoon of household liquid bleach into a cup of cold water Put solution into Base and fi ll with cold water Reinstall Cartridge and tubing Replacement instructions pp 9 10 Let sit fo...

Page 11: ...ips on both sides of the rings that surround the tubing Then pull the tube out with the opposite hand 6 Unscrew to remove the Retaining Ring Fig 37 7 Lift the handle on the Bracket Pull straight up to...

Page 12: ...open the supply shut off valve Fig 45B NOTE It will take a short time for water to saturate the Cartridge and flow from the Diverter Flush for a minimum of 5 U S gallons 20 liters approximately 5 15...

Page 13: ...Faucet Spout WTI 0937 Bracket O Ring WTI 0426 Elbow Set WTI 0618 eSpring Kit Handle WTI 0936 Base WTI 0903 5 16 to 1 4 Connector WTI 0874 eSpring Kit Mount WTI 0938 Bracket WTI 0706 1 4 Tubing 3 ft 9...

Page 14: ...Straight Connector WTI 0600 Aerator WTI 0650 1 4 Straight Connector WTI 0446 5 16 x 5 16 Straight Connector WTI 0902 5 16 Tubing 3 ft 91 m WTI 0882 Diverter WTI 0651 1 4 Plug WTI 0447 Angle Stop Adap...

Page 15: ...COVER This Limited Warranty does not cover a Any eSpring Water Purifier that has been subjected to any use that is different than or inconsistent with the use instructions in the eSpring Water Purifi...

Page 16: ...AIMABLE WARRANTY INCLUDING BUT NOT LIMITED TO THE WARRANTY OR CONDITION OF MERCHANTABILITY AND THE WARRANTY OR CONDITION OF FITNESS FOR A PARTICULAR PURPOSE SHALL BE FOR TERMS EXTENDING BEYOND THE DUR...

Page 17: ...peut tre couvert par un ou plusieurs des brevets am ricains suivants 5 529 689 5 573 666 5 738 780 6 368 504 6 436 299 6 514 420 6 673 250 6 806 649 6 825 620 6 831 417 6 917 163 6 984 320 7 153 178 7...

Page 18: ...net eSpring sous le comptoir 10 0189 Installation d un robinet ou distributeur NON eSpring sous le comptoir 11 0720 Consultez la perspective clat e du Purificateur d Eau ci dessous pour obtenir le nom...

Page 19: ...raisons m dicales vous avez besoin d une eau d une puret exceptionnelle veuillez consulter votre fournisseur de soins de sant avant toute utilisation REMARQUES IMPORTANTES Le Purificateur d Eau eSpri...

Page 20: ...che pas connectez l adaptateur textur appropri aux filetages internes et le brise jet au bout du robinet Sch ma 4 c Si le filetage du robinet est interne connectez l adaptateur appropri au filetage ex...

Page 21: ...nir de l aide a Pour le robinet eSpring Si vous avez besoin de percer un nouveau trou son diam tre devra se situer entre 1 32 mm et 1 38 mm moins de 3 15 16 100 mm du bac de l vier et au moins 1 32 mm...

Page 22: ...Sch ma 21 REMARQUE Si le robinet est toujours l che il se peut que vous ayez besoin d une bague d espacement suppl mentaire Reportez vous la liste des pi ces p 11 4 Enlevez le bo tier sup rieur du Pu...

Page 23: ...doivent tre utilis s entre la valve de l alimentation en eau et le Purificateur d Eau eSpring 7 Ins rez le tube ROUGE du r gulateur de pression au port large du support de fixation Ins rez l extr mit...

Page 24: ...ouche Il reste moins de 10 de dur e de vie de la cartouche Bleu Bleu Bleu Dernier segment clignote Une fois au d but du passage de l eau teint Commandez une cartouche de rechange Fin de la dur e de vi...

Page 25: ...un raccord Tubage ab m en surface Tubage pas ins r assez loin Enlevez le tubage p 9 Sch ma 32 Marquez le tubage p 5 Sch ma 25 Installez le tubage p 5 Sch ma 27 L eau fuit au niveau du raccord filet o...

Page 26: ...eau froide R installez la cartouche et le tubage Instructions de remplacement p 9 10 Laissez agir pendant 10 minutes Faites couler l eau dans le Syst me pendant au moins 5 minutes avant de l utiliser...

Page 27: ...c t s des rondelles autour du tubage Puis retirez le tubage avec l autre main 6 D vissez la bague de blocage pour l enlever Sch ma 37 6 Soulevez la poign e du support de fixation Tirez droit vers le h...

Page 28: ...arr t Sch ma 45B REMARQUE Il faudra un petit moment pour que l eau sature la cartouche et coule de la d rivation Laisser couler au moins 5 gallons U S 20 litres environ 5 15 minutes pour enlever les...

Page 29: ...des WTI 0618 Trousse de Poign e eSpring WTI 0936 Socle WTI 0903 Raccord de 5 16 1 4 WTI 0874 Trousse de montage eSpring WTI 0938 Support de fixation WTI 0706 Tubage de 1 4 3 pieds 0 91 m WTI 0875 Trou...

Page 30: ...rice arr t d querre raccord en T pour conduite d eau froide WTI 0894 Rondelle de d rivation WTI 0821 Raccord droit de 3 8 x 5 16 WTI 0448 Silicone Dow 111 WTI 0895 ACCESSOIRES ET PI CES DE RECHANGE Co...

Page 31: ...PAS COUVERT PAR CETTE GARANTIE LIMIT E Cette Garantie Limit e ne couvre pas a Tout Purificateur d Eau eSpring ayant t soumis tout usage autre que ou incompatible avec les instructions d utilisation d...

Page 32: ...SE LIMITER LA GARANTIE OU CONDITION DE COMMERCIABILIT ET LA GARANTIE OU CONDITION D ADAPTATION UN USAGE PARTICULIER DEVRA TRE POUR LES MODALIT S S TENDANT AU DEL DE LA DUR E DE LA GARANTIE LIMIT E EXP...

Page 33: ...ar protegido por una o m s de las siguientes patentes de los Estados Unidos 5 529 689 5 573 666 5 738 780 6 368 504 6 436 299 6 514 420 6 673 250 6 806 649 6 825 620 6 831 417 6 917 163 6 984 320 7 15...

Page 34: ...Consulte la ilustraci n del purificador de agua para ayuda con los nombres de las partes INSTALACI N Y MANTENIMIENTO Antes de comenzar la instalaci n por favor revise el manual del propietario minuci...

Page 35: ...eza excepcional consulte a su proveedor de atenci n m dica antes de usar el sistema NOTAS IMPORTANTES El Purificador de agua eSpring est dise ado para usarse solamente con agua fr a y bacteriol gicame...

Page 36: ...con rosca interna y arandela en el extremo de su llave Fig 4 c Si las roscas de su llave son internas conecte el adaptador adecuado con rosca externa al extremo de su llave Fig 5 CONEXI N DE LA MANGUE...

Page 37: ...un nuevo orificio deber ser de 1 32 mm a 1 38 mm de di metro menos de 3 15 16 100 mm desde el fregadero y por lo menos 1 32 mm desde la pared Antes de perforar aseg rese de que quede suficiente espac...

Page 38: ...sible que necesite un espaciador adicional Consulte la lista de componentes de servicio p g 11 4 Quite la cubierta superior del purificador de agua Desmonte el m dulo electr nico Fig 22 5 Inserte los...

Page 39: ...y el purificador de agua eSpring 7 Inserte el tubo ROJO del ensamblaje del regulador de presi n en el orificio grande del soporte Inserte el extremo del tubo AZUL marcado a 5 8 15 mm en el orificio p...

Page 40: ...ueda 10 de vida til del cartucho Azul Azul Azul ltimo segmento destellando Una vez al comenzar a fluir Apagado Ordenar cartucho de repuesto Fin de vida til del cartucho Azul Rojo Destellando Apagado C...

Page 41: ...or de empalme Manguera da ada en la superficie La manguera no se insert lo suficiente Remover la manguera p g 9 Fig 32 Marcar la manguera p g 5 Fig 25 Instalar la manguera p g 5 Fig 27 El agua gotea e...

Page 42: ...n en la base y llene 1 4 con agua fr a Vuelva a instalar el cartucho y la manguera instrucciones de reemplazo p gs 9 10 Espere 10 minutos Deje correr el agua por el sistema durante por lo menos 5 min...

Page 43: ...os de los empaques que rodean la manguera A continuaci n jale el tubo con la mano opuesta 6 Destornille para remover el anillo de retenci n Fig 37 6 Levante la manija del soporte Lev ntela para sacar...

Page 44: ...45B NOTA Tardar un tiempo corto para que el agua sature el cartucho y fluya del desviador Deje correr el agua 5 galones 20 litros aproximadamente 5 a 15 minutos para eliminar las bolsas de aire y el p...

Page 45: ...Paquete de manija de llave eSpring WTI 0936 Base WTI 0903 Conector de 5 16 a 1 4 WTI 0874 Paquete de montaje eSpring WTI 0938 Soporte WTI 0706 Manguera de 1 4 3 pies 0 91 m WTI 0875 Paquete del desvia...

Page 46: ...ula de ngulo con adaptador de detenci n T para l nea de agua fr a WTI 0894 Arandela para el desviador WTI 0821 Conector recto de 3 8 x 5 16 WTI 0448 Silicona Dow 111 WTI 0895 ACCESORIOS Y REFACCIONES...

Page 47: ...para el comprador original QU NO CUBRE LA GARANT A LIMITADA La garant a limitada no cubre a Ning n purificador de agua eSpring que haya sido sometido a cualquier uso distinto o incongruente con las in...

Page 48: ...CIALES DICHA GARANT A NO RENUNCIABLE INCLUYENDO ENTRE OTRAS LA GARANT A O CONDICI N PARA LA VENTA Y LA GARANT A O BUENA CONDICI N PARA UN OBJETIVO PARTICULAR SER N POR LOS T RMINOS QUE SE EXTIENDEN M...

Reviews: