ESPi VOLTAR 2.0 SOLAR UPS
____________________________________________________________________________________
Technical Specifications
24
ALARM CONNECTORS
The alarm connections are placed on an RJ-45 cable for easy termination. Refer to Figure
J (shown below) for the pinout information.
PIN1 – (White/Green)
N/A
PIN2 – (Green)
N/A
PIN3 – (Orange/White)
Battery Missing (Battery is not physically connected)
PIN4 – (Blue)
Low Battery Alarm
PIN5 – (Blue/White)
Ground for Low Battery Alarm
PIN6 – (Orange)
Ground for Battery Missing
PIN7 – (Brown/White)
Replace Battery (Battery is at the end of its useful life)
PIN8 – (Brown)
Ground for Replace Battery
Note: Some ONT’s have a single return ground for all alarms. In this case, connect all
return ground wires for the alarms together. Please consult your ONT manufacturer
product guide for proper wiring instructions.