ESI RF BRIDGE
User Guide
version 1.0.4.0
www.elec-solutions.com
© 2014 Electronic Solutions, Inc.
Page 13 of 19
o
none
Move open
!002o;
!000o;
No RQ message report.
Motor moves to fully Open.
All motors move to fully Open.
!000 is a Global “All”
command.
c
none
Move close
!002c;
!000c;
No RQ message report.
Motor moves to fully Closed.
All motors move to fully
Closed.
!000 is a Global “All”
command.
s
none
Stop
!002s;
!000s;
No RQ message report.
Motor stops.
All motors Stop.
!000 is a Global “All”
command.
i
none
Identify
!001i;
!002i;
!000i;
No RQ message report.
Remote blinks (STOP button).
Motor jogs. Yellow LED blinks.
All: motors jog, remotes blink.
Used to identify which motor is
assigned to an RQ address.
!000 is a Global “All”
command.
m
destination*
(00-99)
Move to intermediate
position (2 digit)
!002m23;
No RQ message report.
Motor moves to 23% away from
reference.
Motor is stopped 23% away
from reference.
M
destination
(000-999)
Move to intermediate
position (3 digit)
!002M237;
No RQ message report.
Moves to 23.7% away from
reference.
Motor is stopped 23.7% away
from reference.
NOTE:
The RQ command to
request a 3-digit position (“R”)
is currently not supported.
r
?
Request 2 digit
position now
!002r?;
2 digit position report if
motor is stopped.
For example: !002r23;
Motor is stopped 23% away
from reference.
SCENES
:
Scenes cannot be “defined” while the motor is moving.
d
scene
s
Define a scene
!002dC23;
!000dC23;
No RQ message report.
If
RF Motor, RQ Motor
or
standard motor/RQ motor
control:
jogs twice, but does not move
to the scene.
All motors jog twice, but do
not move to the scene.
Define Scene “C” at 23% away
from reference for this motor.
NOTE:
By default, Scene “0” is
used for the PRESET button
on the SUITE remote.
!000 is a Global “All”
command.
d
scene
s
h = set scene to here
(where we are now)
!002dCh;
!000dCh;
No RQ message report.
Motor jogs twice.
All motors jog twice.
Scene “C” is set at current,
stopped position of motor(s).
!000 is a Global “All”
command.
g
scene
s
Execute scene
!002gC;
!000gC;
No RQ message report.
Motor goes to Scene C.
All motors go to Scene C, if
they are included in the scene.
If motor is already at position
for Scene C, or motor is not in
Scene C, no movement
happens.
!000 is a Global “All”
command.
d
scene
s
NS
Clear a scene
!002dCNS;
!000dCNS;
No RQ message report.
Motor jogs twice.**
All motors jog twice.**
Do not act on Scene “C” for
this motor.
!000 is a Global “All”
command. Clears Scene “C”
on all motors.