background image

800.833.3746

esiergo.com

© 2017 ESI Ergonomic Solutions. All rights reserved.  

2VT  Rev A  1/17

Summary of Contents for VICTORY 2VT-C36-30 Series

Page 1: ...ASSEMBLY AND OPERATION VICTORY Model 2VT C36 24 ___ Model 2VT C36 30 ___ Model 2VT C48 24 ___ Model 2VT C48 30 ___ ___ SLV BLK or WHT 2 LEG ELECTRIC TABLE BASE 2VT Rev A 1 17 ...

Page 2: ...ates to your satisfaction PARTS PROVIDED Cross Channels 2 Legs with Motor 2 Digital Keypad 1 Control Unit 1 Power Cable 1 Motor Cables 2 Top Supports 2 CAUTION Hand tighten screws only Do not use power tools Cable Clamps and Ties Fasteners Feet 2 Foot Plates 2 M6x35 8 M8x12 12 6 3 6 ST 4 8x19 19 ST 2 9x19 2 ADDITIONAL TOOLS REQUIRED 5mm Allen key Phillips screwdriver CAUTION Always check that scre...

Page 3: ...final lengths as shown Center the inner piece in each cross channel STEP 4 Attach the side legs to the cross channels and top supports with six M8x12 screws per leg Use a 5mm Allen key Two screws attach to each cross channel and two screws attach to the top supports STEP 5 Attach a foot plate and foot to each of the side legs with the M6x35 screws First place the foot plate onto the leg with the s...

Page 4: ... in the cross channels 8 total Use the 5mm Allen key to hand tighten STEP 9 Attach the digital keypad using the two ST2 9x19 screws Position the digital keypad on the left or right side of the table according to user preference Align the top of the keypad with the edge of the table so that the controls will be easily accessible STEP 10 Attach the control unit using two ST4 8x19 screws Position the...

Page 5: ...e the DOWN t button Press the UP s and DOWN t buttons to test operation End your test with the legs lowered and unplug the power cord If there are problems with operation check that all cable and cord connections are secure If problems continue call ESI Customer Service STEP 13 Use the cable clamps and ties to secure the cables in position Cables must not interfere with table operation Cables must...

Page 6: ...he control unit will click once when the stop position has been erased SAVING A TABLE POSITION The three memory buttons can be used to save specific positions of the work surface To set a specific position Adjust the work surface to the position you want to save The display on the control pad shows the work surface height Press the Setting button S The display will read S Press the desired Memory ...

Page 7: ...ess UP s until the display reads S5 Then press the Setting button S If the display was set to centimeters it will now be set to inches or vice versa RESET THE CONTROL UNIT TO FACTORY SETTINGS To reset the control unit to factory settings Press and hold memory buttons 1 and 2 and the UP s button Release the three buttons after about five seconds The display will show S and a number for example S5 P...

Page 8: ...800 833 3746 esiergo com 2017 ESI Ergonomic Solutions All rights reserved 2VT Rev A 1 17 ...

Reviews: