ESi Ergo VICTORY 2VT-C36-30 Series Instructions Manual Download Page 6

6

VICTORY 2 LEG ELECTRIC TABLE BASE 

OPERATION

GENERAL OPERATION 

Move the table up or down by pressing UP 

s

 or DOWN 

t

 until 

the work surface reaches the desired height.
The table will continue to move up or down until you release the 
button or until the maximum or minimum height is reached. 

MINIMUM AND MAXIMUM STOP POSITION 

This feature can be used to limit the range of table travel to 
prevent the work surface from hitting items below or above it. 
• The minimum stop position must be in the lower half of the 

movement range, and the maximum stop position must be in 
the upper half.

• Minimum and maximum stop positions must be set separately. 
To set a stop position:
• Move the work surface to the desired minimum or maximum 

height.

• Press and hold both the UP 

s

 and DOWN 

t

 buttons for 10 to 15 

seconds. The control unit will click twice when the stop position 
has been stored.

To erase a stop position:
• Move the work surface to the stop position to be erased.
• Press and hold both the UP 

s

 and DOWN 

t

 buttons for 10 to 15 

seconds. The control unit will click once when the stop position 
has been erased.

SAVING A TABLE POSITION 

The three memory buttons can be used to save specific positions 
of the work surface. To set a specific position:

• Adjust the work surface to the position you want to save. (The 

display on the control pad shows the work surface height.)

• Press the Setting button 

S

. The display will read 

S – –

.

• Press the desired Memory button, 

1

2

 or 

3

. Let’s say you 

pressed 1. The display will read 

S1

.

• The work surface position is now saved. The control unit will 

click twice after about two seconds and the display will show 
the work surface height.

Setting

Button

Memory

Buttons

Table

Height

DOWN

Button

UP

Button

CAUTION: The “zero setting” procedure 

must be completed before operating the 

table. See Step 12 on page 5.

You can set a minimum stop, a 

maximum stop, or both a minimum 

and maximum stop.

Minimum and maximum stops can 

serve the same function as memory 

stops. For example, minimum stop 

could be the user’s standard sitting 

position and maximum stop could 

be the user’s standard standing 

position.

Default stop position for the three 

memory buttons is the lowest height 

of the work surface.

Table movement stops when you 

release the UP 

s

 or DOWN 

t

 button.

Summary of Contents for VICTORY 2VT-C36-30 Series

Page 1: ...ASSEMBLY AND OPERATION VICTORY Model 2VT C36 24 ___ Model 2VT C36 30 ___ Model 2VT C48 24 ___ Model 2VT C48 30 ___ ___ SLV BLK or WHT 2 LEG ELECTRIC TABLE BASE 2VT Rev A 1 17 ...

Page 2: ...ates to your satisfaction PARTS PROVIDED Cross Channels 2 Legs with Motor 2 Digital Keypad 1 Control Unit 1 Power Cable 1 Motor Cables 2 Top Supports 2 CAUTION Hand tighten screws only Do not use power tools Cable Clamps and Ties Fasteners Feet 2 Foot Plates 2 M6x35 8 M8x12 12 6 3 6 ST 4 8x19 19 ST 2 9x19 2 ADDITIONAL TOOLS REQUIRED 5mm Allen key Phillips screwdriver CAUTION Always check that scre...

Page 3: ...final lengths as shown Center the inner piece in each cross channel STEP 4 Attach the side legs to the cross channels and top supports with six M8x12 screws per leg Use a 5mm Allen key Two screws attach to each cross channel and two screws attach to the top supports STEP 5 Attach a foot plate and foot to each of the side legs with the M6x35 screws First place the foot plate onto the leg with the s...

Page 4: ... in the cross channels 8 total Use the 5mm Allen key to hand tighten STEP 9 Attach the digital keypad using the two ST2 9x19 screws Position the digital keypad on the left or right side of the table according to user preference Align the top of the keypad with the edge of the table so that the controls will be easily accessible STEP 10 Attach the control unit using two ST4 8x19 screws Position the...

Page 5: ...e the DOWN t button Press the UP s and DOWN t buttons to test operation End your test with the legs lowered and unplug the power cord If there are problems with operation check that all cable and cord connections are secure If problems continue call ESI Customer Service STEP 13 Use the cable clamps and ties to secure the cables in position Cables must not interfere with table operation Cables must...

Page 6: ...he control unit will click once when the stop position has been erased SAVING A TABLE POSITION The three memory buttons can be used to save specific positions of the work surface To set a specific position Adjust the work surface to the position you want to save The display on the control pad shows the work surface height Press the Setting button S The display will read S Press the desired Memory ...

Page 7: ...ess UP s until the display reads S5 Then press the Setting button S If the display was set to centimeters it will now be set to inches or vice versa RESET THE CONTROL UNIT TO FACTORY SETTINGS To reset the control unit to factory settings Press and hold memory buttons 1 and 2 and the UP s button Release the three buttons after about five seconds The display will show S and a number for example S5 P...

Page 8: ...800 833 3746 esiergo com 2017 ESI Ergonomic Solutions All rights reserved 2VT Rev A 1 17 ...

Reviews: