background image

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11340 V2.0 R1.0  Manual 

Page 8 of 9 

 
 
 
Starting with firmware version V1.18_38, it is no longer necessary to press the reset button of the 1-Wire 
controller / 1-Wire gateway for the update. You can find a video about the firmware update on our website under 
"Service and Support, Support Videos". 
 

15.1      Recovery Function Firmware-update 

Should an error occur during the firmware update e.g. losing power while updating the 
firmware, a recovery function can be started. Press and hold the reset button (the reset 
button is located beneath hole no. 30 at module top side). Then start the update in Config-
Tool 3 and release the reset button after 1 second after the update has been started. The 
update should start now.  
When the updated is completed we recommend to disconnect the 1-Wire Controller / 1-Wire 
Gateway for approx. 30 seconds, then restart again. If any issues should occur when 
installing the update, please contact the ESERA support team: E-Mail

[email protected]

 

 

16 

ESERA ASCII text protocol 

The ESERA text protocol in ASCII format can be used very easily for configuration and 
analysis. Special emphasis was placed here on good readability and traceability. With the ESERA text protocol, 
"GET" and "SET" commands are used which probably every programmer has already used in his own projects. 
The ESERA text protocol is completely disclosed and documented. The latest version of the ESERA protocol 
description ("Programming Manual") can be found within Config Tool 3 under "DOKU" or in the download area of 
the article on our website. 
 

17 

Operating conditions 

The module may only be operated at the voltages and ambient conditions specified for it. The device can be 
operated in any position. The device is intended for use in dry and dust-free rooms.  
If condensation forms, wait for at least 2 hours to acclimatise. 
The modules may only be put into operation under the supervision of a qualified electrician. Do not operate the 
module in an environment where flammable gases, vapours or dust are present or could be present. 
 

18 

Assembly 

The installation site must be protected against moisture. The device may only be used in dry indoor rooms. 
The device is intended for mounting inside a control cabinet as a stationary device.  
 

19 

Disposal note 

Do not dispose of the device within the household waste! 
According to the directive concerning old electrical and electronic appliances, 
electronic devices must be disposed of via the collecting points for old electronic 
appliances! 
 

20 

Safety instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be observed, especially 
VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During 
installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected 
from the power supply and electrical charges stored in the components inside the device have been discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or 
breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable 
has been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics for 
a part or assembly are, how to connect an external circuit, which external components or additional devices can be 
connected or which values these external components may have, a qualified electrician must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

1-Wire Controller 1 

Abbildung 1-Wire 

Controller 1 

Summary of Contents for Auto-E-Connect 11340

Page 1: ...ing to the safety notes 2 Product description You can communicate with your smart home or industrial controller e g ESERA Station IP Symcon Loxone or FHEM via TCP or UDP protocol with the 1 Wire Controller 2 Autonomous management The 1 Wire Controller 2 is designed for the autonomous management of a 1 Wire Network You no longer need to worry about 1 Wire commands or formulas for evaluating sensor ...

Page 2: ... of 1 Wire sensors and actuators on the 1 Wire bus It is optimized for industrial applications and enables significant added value beyond the sensor and chip data The Auto E Connect function automatically recognizes ESERA chips sensors and actuators starts suitable libraries and outputs fully formatted data The Auto E Connect functionality will be available from mid 2020 via 1 Wire Controllers 1 W...

Page 3: ... 3 Interference radiation RoHS 7 Display LED The module has various display LEDs In the following the function of the displays Display Description Function LED Green PWR Display for supply voltage LED Green DATA LED flashes 3 times after power on Flashes at 1 Wire activity Flashes while transferring data by the data interface Flashes very quickly if KAL Receive has been activated and the KAL messa...

Page 4: ...c duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11340 V2 0 R1 0 Manual Page 4 of 9 8 Connection www esera de ...

Page 5: ...for digital output 5 26 Digital output 5 normally open contact max 5A 30 Reset Button inside 32 GND negative 1 Wire Bus 33 1 Wire Data 34 5 V voltage supply for 1 Wire Bus max 200 mA 35 12 V voltage supply for 1 Wire Bus max 250 mA Module bottom side supply voltage digital input and analog output 1 GND negative digital input isolated to negative supply 2 digital input 1 10 30 VDC 3 digital input 2...

Page 6: ... complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11340 V2 0 R1 0 Manual Page 6 of 9 9 Connection example 1 Wire Controller sensors and actuators and termination www esera de ...

Page 7: ...gration in FHEM For the integration into the open source automation software FHEM we provide a software module for easy integration of the 4 fold analog input into FHEM via 1 Wire Controller 1 Wire Gateway Thus evaluation scripts are no longer necessary Details can be found on the ESERA website under Compatible controllers Central FHEM integration Further details can be found on our webpage https ...

Page 8: ...where flammable gases vapours or dust are present or could be present 18 Assembly The installation site must be protected against moisture The device may only be used in dry indoor rooms The device is intended for mounting inside a control cabinet as a stationary device 19 Disposal note Do not dispose of the device within the household waste According to the directive concerning old electrical and...

Page 9: ...r damages for example for non performance fault in contracting breach of secondary contractual obligations consequential damages damages resulting from unauthorized usage and other legal grounds are excluded Excepting to this ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence Claims made under the Product Liability Act are not affected If...

Reviews: