10 

Software  

Data interface ESERA ASCII Text protocol 

To configure the Ethernet interface please use ESERA Config-Tool 3. This software is available for download on 
our webpage.  
 

11 

Integration in IP-Symcon / ESERA-Station 

On our website, we provide ESERA IP-Symcon software modules for easy integration of the 4-fold analog 
input in IP-Symcon via 1-Wire Controller / 1-Wire Gateway. Thus, no scripts are necessary anymore. Details 
can be found on the ESERA Website under "Compatible controllers / central units / IP-Symcon-

Integration”: 

https://www.esera.de/kompatible-steuerungen-zentralen/ip-symcon-integration/. 

 

For the conventional connection via 1-Wire Bus coupler you will find a script in the article download area. Details 
can be found within the example script. 
 

12 

Integration in Loxone 

In the shop we provide an example project for the reading of analog voltages via 4-fold analog input via 1-
Wire Controller 1. Details see here: 

 

Further details can be found here: 

https://www.esera.de/kompatible-steuerungen-zentralen/loxone-

integration/demo-1-wire-controller-1-loxone-integration/ 

 

13 

Integration in FHEM 

For the integration into the open source automation software FHEM we provide a software module for easy 
integration of the 4-fold analog input into FHEM via 1-Wire Controller / 1-Wire Gateway. Thus, evaluation 
scripts are no longer necessary. 
Details can be found on the ESERA website under "Compatible controllers / Central/FHEM integration". 
Further details can be found on our webpage: 

https://www.esera.de/kompatible-steuerungen-zentralen/fhem-

integration/ 

 

14 

Configuration and communication with 1-Wire Controller 2  

1-Wire Controller 2 offers various configuration and formatting options. All options can be read out and 
controlled by the ESERA Config-Tool 3.  
Since communication between the 1-Wire Controller 2 and Config Tool 3 takes place via the open ESERA 
ASCII text protocol, you can also exchange data with any terminal program (e.g. Hercules or Putty) via 
UDP/TCPIP with the 1-Wire Controller 2 at any time and carry out the configuration.  
For details on the communication commands, refer to the document "Programming Manual", which you can 
find in the download area of the ESERA online shop and within the Config Tool 3/Docu. 
 

15 

Firmware-Update 

Firmware will be updated by using a Config-Tool 3 
software which can be found at 

the “DEBUG/DATA” 

tab. By clicking the button “DOWNLOAD 
FIRMWARE” a new window opens to download 
new software (firmware) for the 1-Wire Controller / 
1-Wire Gateway. 
The firmware is applicable for all device versions of 
the 1-Wire Controllers and 1-Wire Gateways. The 
corresponding functionality is activated on the 
installed device in an adapted way. 
 
 
 
 
 
 
 
 

Summary of Contents for Auto-E-Connect 11340

Page 1: ...ing to the safety notes 2 Product description You can communicate with your smart home or industrial controller e g ESERA Station IP Symcon Loxone or FHEM via TCP or UDP protocol with the 1 Wire Controller 2 Autonomous management The 1 Wire Controller 2 is designed for the autonomous management of a 1 Wire Network You no longer need to worry about 1 Wire commands or formulas for evaluating sensor ...

Page 2: ... of 1 Wire sensors and actuators on the 1 Wire bus It is optimized for industrial applications and enables significant added value beyond the sensor and chip data The Auto E Connect function automatically recognizes ESERA chips sensors and actuators starts suitable libraries and outputs fully formatted data The Auto E Connect functionality will be available from mid 2020 via 1 Wire Controllers 1 W...

Page 3: ... 3 Interference radiation RoHS 7 Display LED The module has various display LEDs In the following the function of the displays Display Description Function LED Green PWR Display for supply voltage LED Green DATA LED flashes 3 times after power on Flashes at 1 Wire activity Flashes while transferring data by the data interface Flashes very quickly if KAL Receive has been activated and the KAL messa...

Page 4: ...c duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11340 V2 0 R1 0 Manual Page 4 of 9 8 Connection www esera de ...

Page 5: ...for digital output 5 26 Digital output 5 normally open contact max 5A 30 Reset Button inside 32 GND negative 1 Wire Bus 33 1 Wire Data 34 5 V voltage supply for 1 Wire Bus max 200 mA 35 12 V voltage supply for 1 Wire Bus max 250 mA Module bottom side supply voltage digital input and analog output 1 GND negative digital input isolated to negative supply 2 digital input 1 10 30 VDC 3 digital input 2...

Page 6: ... complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11340 V2 0 R1 0 Manual Page 6 of 9 9 Connection example 1 Wire Controller sensors and actuators and termination www esera de ...

Page 7: ...gration in FHEM For the integration into the open source automation software FHEM we provide a software module for easy integration of the 4 fold analog input into FHEM via 1 Wire Controller 1 Wire Gateway Thus evaluation scripts are no longer necessary Details can be found on the ESERA website under Compatible controllers Central FHEM integration Further details can be found on our webpage https ...

Page 8: ...where flammable gases vapours or dust are present or could be present 18 Assembly The installation site must be protected against moisture The device may only be used in dry indoor rooms The device is intended for mounting inside a control cabinet as a stationary device 19 Disposal note Do not dispose of the device within the household waste According to the directive concerning old electrical and...

Page 9: ...r damages for example for non performance fault in contracting breach of secondary contractual obligations consequential damages damages resulting from unauthorized usage and other legal grounds are excluded Excepting to this ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence Claims made under the Product Liability Act are not affected If...

Reviews: