User Guide 

1-Wire Controller 2 

 

 

 

  1-Wire Controller / Gateway for autonomous 

communication  among SPS and a 1-Wire Sensor and 
Actuator Network 

  Fast readout of all 1-Wire devices in  

1-2 seconds cycle  

  Data output as ASCII text protocol 

  Processed sensor and actuator data  

  Status for each sensor and actuator can be called up 

  Comfortable configuration program 

  No additional drivers necessary 

  Power supply for 1-Wire Network 

  Designed for all 1-Wire Network sizes 

  Top-hat rail housing for control cabinet installation  

  Management of all ESERA-Automation and many  

Standard 1-Wire Sensors and Actuators (e.g. switching 
modules)  

 

 

 

 

Introduction 

Before you start assembling the 1-Wire Controller 2 and before you take the device into operation, please 
read this assembly and operating instruction carefully to the end, especially the section referring to the safety 
notes. 
 

Product description

   

 

 

 

  

You can communicate with your smart home or industrial controller, e.g. ESERA Station, IP-Symcon,  
Loxone or FHEM via TCP or UDP protocol with the 1-Wire Controller 2.  

 
Autonomous management 

The 1-Wire Controller 2 is designed for the autonomous management of a 1-Wire Network. You no longer 
need to worry about 1-Wire commands or formulas for evaluating sensor data. The 1-Wire Controller 2 
automatically scans the 1-Wire Network for new sensors and actuators and provides the corresponding data 
in plain text via ASCII protocol, depending on the device found.  
 

Formatted data output 

The 1-Wire Controller 2 prepares sensor and actuator data that have been checked for plausibility, e.g. for 
temperature sensors in °C with 2 decimal places. Only a division by 100 is necessary. Within the 1-Wire 
Controller 2, product-specific conversion formulas are available for almost all 1-Wire sensors or actuators offered 
by ESERA. 

 
Designed for all 1-Wire Networks 

The 1-Wire interface of the 1-Wire Controller 2 is specially designed to safely operate all sizes of 1-Wire 
Networks, even with long cable runs. 1-Wire sensors can be operated simultaneously in parasitic or normal 
mode. 
The currently strongest 1-Wire interface for maximum data security, even for complex network structures, 
has been installed.   

Summary of Contents for Auto-E-Connect 11340

Page 1: ...ing to the safety notes 2 Product description You can communicate with your smart home or industrial controller e g ESERA Station IP Symcon Loxone or FHEM via TCP or UDP protocol with the 1 Wire Controller 2 Autonomous management The 1 Wire Controller 2 is designed for the autonomous management of a 1 Wire Network You no longer need to worry about 1 Wire commands or formulas for evaluating sensor ...

Page 2: ... of 1 Wire sensors and actuators on the 1 Wire bus It is optimized for industrial applications and enables significant added value beyond the sensor and chip data The Auto E Connect function automatically recognizes ESERA chips sensors and actuators starts suitable libraries and outputs fully formatted data The Auto E Connect functionality will be available from mid 2020 via 1 Wire Controllers 1 W...

Page 3: ... 3 Interference radiation RoHS 7 Display LED The module has various display LEDs In the following the function of the displays Display Description Function LED Green PWR Display for supply voltage LED Green DATA LED flashes 3 times after power on Flashes at 1 Wire activity Flashes while transferring data by the data interface Flashes very quickly if KAL Receive has been activated and the KAL messa...

Page 4: ...c duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11340 V2 0 R1 0 Manual Page 4 of 9 8 Connection www esera de ...

Page 5: ...for digital output 5 26 Digital output 5 normally open contact max 5A 30 Reset Button inside 32 GND negative 1 Wire Bus 33 1 Wire Data 34 5 V voltage supply for 1 Wire Bus max 200 mA 35 12 V voltage supply for 1 Wire Bus max 250 mA Module bottom side supply voltage digital input and analog output 1 GND negative digital input isolated to negative supply 2 digital input 1 10 30 VDC 3 digital input 2...

Page 6: ... complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11340 V2 0 R1 0 Manual Page 6 of 9 9 Connection example 1 Wire Controller sensors and actuators and termination www esera de ...

Page 7: ...gration in FHEM For the integration into the open source automation software FHEM we provide a software module for easy integration of the 4 fold analog input into FHEM via 1 Wire Controller 1 Wire Gateway Thus evaluation scripts are no longer necessary Details can be found on the ESERA website under Compatible controllers Central FHEM integration Further details can be found on our webpage https ...

Page 8: ...where flammable gases vapours or dust are present or could be present 18 Assembly The installation site must be protected against moisture The device may only be used in dry indoor rooms The device is intended for mounting inside a control cabinet as a stationary device 19 Disposal note Do not dispose of the device within the household waste According to the directive concerning old electrical and...

Page 9: ...r damages for example for non performance fault in contracting breach of secondary contractual obligations consequential damages damages resulting from unauthorized usage and other legal grounds are excluded Excepting to this ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence Claims made under the Product Liability Act are not affected If...

Reviews: