background image

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11337 V2.0 R1.0  Manual 

Page 10 of 10 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be 
installed upstream or a suitable power supply can be used.  

 

After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, 

https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance

) must be carried  

 

21 

Warranty 

ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship 
defects and have the contractually assured characteristics. The statutory warranty period of two years begins from date 
of invoice. The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims 
for damages, for example, for non-performance, fault in contracting, breach of secondary contractual obligations, 
consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. Excepting 
to this, ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence. 
Claims made under the Product Liability Act are not affected. 
If defects occur for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is 
faulty, the buyer has the right to have the original purchase price refunded or a reduction of the purchase price.  
ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for 
technical or electronic errors in the online offer. 
We develop our products further and we reserve the right to make changes and improvements to any of the products 
described in this documentation without prior notice. If you need documentation or information about older product 
versions, contact us by email a

[email protected]

 

 

22 

Trademarks 

All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are 
trademarks, registered trademarks or other copyright or trademarks or titles or legally protected designations of their 
respective owners and are hereby expressly recognized as such by us. The mention of these designations, logos, 
names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part 
of ESERA GmbH on these designations, logos, names and trademarks. Moreover, from their appearance on 
ESERA GmbH webpages it cannot be concluded that designations, logos, names and trademarks are free of 
commercial property rights. 

ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH. 

 

23 

Contact 

ESERA GmbH  
Adelindastrasse 20 
87600 Kaufbeuren 
GERMANY 
Tel.: +49 8341 999 80-0

 

Fax: +49 8341 999 80-10

 

www.esera.de

 

[email protected]

 

WEEE-Number: DE30249510

 

 

 
 

Summary of Contents for 1-Wire Gateway 20 Modbus TCP

Page 1: ...TCP and before you take the device into operation please read this assembly and operating instruction carefully to the end especially the section referring to the safety notes We recommend to use Config Tool 3 for all kind of setup and configuration tasks Please find the latest release on our website at www esera de Please also refer to the Help Support section to find the user guide for Config To...

Page 2: ...luding an integrated backup battery Data plausibility check is possible at any time Power supply Input voltage for 1 Wire Gateway 20 Modbus is 9 30 VDC Therefore it can be used for 12 V as well as 24 VDC industrial applications Appropriate hat rail mounted power supplies or power plugs can be found in our webshop 3 Auto E Connect Support The ESERA Auto E Connect 1 Wire Plug and Play system will be...

Page 3: ... Conformity EN 50090 2 2 EN 61000 4 2 ESD EN 61000 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 Fault free operation EN 61000 6 3 Stray radiation RoHS 7 LED indicators The module status will be displayed by various LEDs Please refer to the following table for their functions LED status Description Function LED Green PWR power indicator LED Green DATA LED flashes 3 times after power on...

Page 4: ...c duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11337 V2 0 R1 0 Manual Page 4 of 10 8 Connection www esera de ...

Page 5: ...ned 16 GND negative supply voltage 17 Positive supply voltage Module top side Digital Output and 1 Wire Bus 18 main supply for digital output 1 2 19 digital output 1 max 8 A 20 digital output 2 max 8 A 21 main supply for digital output 3 4 22 digital output 3 max 8 A 23 digital output 4 max 8 A 24 digital output 5 break contact max 5A 25 main supply for digital output 5 26 digital output 5 make co...

Page 6: ...ser guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11337 V2 0 R1 0 Manual Page 6 of 10 9 Connection Example 1 Wire Gateway sensors and actuators www esera de ...

Page 7: ...ntroller 1 loxone integration 13 Integration in FHEM We provide a software module for easy integration in the Open Source automation software FHEM of the 4 fold analog input into FHEM by 1 Wire Controller 1 Wire Gateway Using this software scripts are no longer necessary Further details can be found on our webpage https www esera de kompatible steuerungen zentralen fhem integration 14 Configuratio...

Page 8: ... and SET commands The ESERA text protocol is totally open and documented The latest version of the ESERA protocol description is available for download in our webshop https www esera de produkte software downloads firmware 1 wire controller 1 wire gateway as well as in the ESERA Config Tool 3 download area 16 2 Modbus TCP protocol 1 Wire Gateway 20 Modbus communication to ESERA text protocol or Mo...

Page 9: ... sure that the unit is disconnected from the mains Components modules or devices may only be put into service if they are mounted in a contact proof housing During installation they must not have power applied Tools may only be used on devices components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside t...

Page 10: ...ade under the Product Liability Act are not affected If defects occur for which the ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical o...

Reviews: