17 

Operating conditions 

The operation of the assembly group can take place only on condition of observing the required voltage 
and the ambient conditions. The operating position of the device is irrelevant. The device is meant to be 
used in dry and dust-free areas. 
Should condensed water build up, an acclimatization period of at least 2 hours must pass. 
Assembly groups and components do not belong into the hands of children! 
The building group can be operated only under the supervision of an electrically skilled person. 
In industrial facilities, the accident prevention regulations of the federation of industrial professional 
associations for electrical installations and equipments must be observed. 
Do not operate the assembly group in an environment with inflammable gases, vapours or dusts or in an 
environment where such gases, vapours or dusts may be found. 
 

18 

Assembly 

The location of the assembly must be protected against humidity. The device may be used only in dry 
inside spaces and protected outside areas. The device is designed to be assembled as a fixed device 
within a switchboard. 
 

19 

Disposal note 

Do not dispose of the device within the household waste! 
According to the directive concerning old electrical and electronic appliances, 
electronic devices must be disposed of via the collecting points for old electronic 
appliances! 
 

20 

Safety instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be observed, 
especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. 
During installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are 
disconnected from the power supply and electrical charges stored in the components inside the device have 
been discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults 
or breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty 
cable has been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical 
characteristics for a part or assembly are, how to connect an external circuit, which external components or 
additional devices can be connected or which values these external components may have, a qualified 
electrician must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the 
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly 
or disassembly of cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

Summary of Contents for 1-Wire Gateway 20 Modbus TCP

Page 1: ...TCP and before you take the device into operation please read this assembly and operating instruction carefully to the end especially the section referring to the safety notes We recommend to use Config Tool 3 for all kind of setup and configuration tasks Please find the latest release on our website at www esera de Please also refer to the Help Support section to find the user guide for Config To...

Page 2: ...luding an integrated backup battery Data plausibility check is possible at any time Power supply Input voltage for 1 Wire Gateway 20 Modbus is 9 30 VDC Therefore it can be used for 12 V as well as 24 VDC industrial applications Appropriate hat rail mounted power supplies or power plugs can be found in our webshop 3 Auto E Connect Support The ESERA Auto E Connect 1 Wire Plug and Play system will be...

Page 3: ... Conformity EN 50090 2 2 EN 61000 4 2 ESD EN 61000 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 Fault free operation EN 61000 6 3 Stray radiation RoHS 7 LED indicators The module status will be displayed by various LEDs Please refer to the following table for their functions LED status Description Function LED Green PWR power indicator LED Green DATA LED flashes 3 times after power on...

Page 4: ...c duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11337 V2 0 R1 0 Manual Page 4 of 10 8 Connection www esera de ...

Page 5: ...ned 16 GND negative supply voltage 17 Positive supply voltage Module top side Digital Output and 1 Wire Bus 18 main supply for digital output 1 2 19 digital output 1 max 8 A 20 digital output 2 max 8 A 21 main supply for digital output 3 4 22 digital output 3 max 8 A 23 digital output 4 max 8 A 24 digital output 5 break contact max 5A 25 main supply for digital output 5 26 digital output 5 make co...

Page 6: ...ser guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11337 V2 0 R1 0 Manual Page 6 of 10 9 Connection Example 1 Wire Gateway sensors and actuators www esera de ...

Page 7: ...ntroller 1 loxone integration 13 Integration in FHEM We provide a software module for easy integration in the Open Source automation software FHEM of the 4 fold analog input into FHEM by 1 Wire Controller 1 Wire Gateway Using this software scripts are no longer necessary Further details can be found on our webpage https www esera de kompatible steuerungen zentralen fhem integration 14 Configuratio...

Page 8: ... and SET commands The ESERA text protocol is totally open and documented The latest version of the ESERA protocol description is available for download in our webshop https www esera de produkte software downloads firmware 1 wire controller 1 wire gateway as well as in the ESERA Config Tool 3 download area 16 2 Modbus TCP protocol 1 Wire Gateway 20 Modbus communication to ESERA text protocol or Mo...

Page 9: ... sure that the unit is disconnected from the mains Components modules or devices may only be put into service if they are mounted in a contact proof housing During installation they must not have power applied Tools may only be used on devices components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside t...

Page 10: ...ade under the Product Liability Act are not affected If defects occur for which the ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical o...

Reviews: