Art. No. 11337  

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11337 V2.0 R1.0  Manual 

Page 7 of 10 

10 

Data interface Modbus TCP and ESERA ASCII text protocol 

The Ethernet interface is configured using the Windows ESERA program "Config-Tool 3".  
You can find this program in the download area of the ESERA online shop. 
 

11 

Integration in IP-Symcon / ESERA-Station 

ESERA IP-Symcon software modules are provided at our webpage for easy integration of the 4-fold analog 
input in IP-Symcon by using a 1-Wire Controller / 1-Wire Gateway. Using software scripts are no longer 
necessary. Further details can be found on our webpage

https://www.esera.de/kompatible-steuerungen-

zentralen/ip-symcon-integration/. 

 
A script for regular connections by 1-Wire Bus Coupler is also available for download on our webpage. 
Further details can be found in the sample script. 
 

12 

Integration in Loxone 

We provide a sample project e.g. for read out analog voltages by 4-fold analog input via  
1-Wire Controller 1 in our webshop.

 

Further details can be found here: 

https://www.esera.de/kompatible-steuerungen-zentralen/loxone-

integration/demo-1-wire-controller-1-loxone-integration/ 

 

13 

Integration in FHEM 

We provide a software module for easy integration in the Open Source automation software FHEM of the 
4-fold analog input into FHEM by 1-Wire Controller / 1-Wire Gateway. Using this software scripts are no 
longer necessary. Further details can be found on our webpage: 

https://www.esera.de/kompatible-

steuerungen-zentralen/fhem-integration/ 

 

14 

Configuration and communication with 1-Wire Gateway 20  

1-Wire Gateway 20 offers various configuration and formatting options. All options can be read out and 
controlled by the ESERA Config-Tool 3. 1-Wire Gateway and Config-Tool 3 communication is based on 
an open ESERA ASCII text protocol. Therefore configuration and data transfer with any terminal program 
(such as Hercules or Putty) by UDP/TCPIP and 1-Wire Gateway 20 is possible at any time. For detailed 
communication commands please refer to the “

Programming Manual

 which is available for download in 

our webshop. 
 

15 

Firmware-Update 

Firmware will be updated by using a Config-Tool 
3 software which can be found at the 
“DEBUG/DATA” tab. By clicking the button 
“DOWNLOAD FIRMWARE” a new window 
opens to download new software (firmware) for 
the 1-Wire Controller / 1-Wire Gateway. 
This firmware is compatible with all releases of 
the 1-Wire Controller and 1-Wire Gateways. The 
features are individually unlocked at the installed 
device. Starting with firmware version V1.18_38 
the reset button of the 1-Wire Controller / 1-Wire 
Gateway does not need to be pressed for 
updates anymore. 
 
 
 

 
 
 
 

Summary of Contents for 1-Wire Gateway 20 Modbus TCP

Page 1: ...TCP and before you take the device into operation please read this assembly and operating instruction carefully to the end especially the section referring to the safety notes We recommend to use Config Tool 3 for all kind of setup and configuration tasks Please find the latest release on our website at www esera de Please also refer to the Help Support section to find the user guide for Config To...

Page 2: ...luding an integrated backup battery Data plausibility check is possible at any time Power supply Input voltage for 1 Wire Gateway 20 Modbus is 9 30 VDC Therefore it can be used for 12 V as well as 24 VDC industrial applications Appropriate hat rail mounted power supplies or power plugs can be found in our webshop 3 Auto E Connect Support The ESERA Auto E Connect 1 Wire Plug and Play system will be...

Page 3: ... Conformity EN 50090 2 2 EN 61000 4 2 ESD EN 61000 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 Fault free operation EN 61000 6 3 Stray radiation RoHS 7 LED indicators The module status will be displayed by various LEDs Please refer to the following table for their functions LED status Description Function LED Green PWR power indicator LED Green DATA LED flashes 3 times after power on...

Page 4: ...c duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11337 V2 0 R1 0 Manual Page 4 of 10 8 Connection www esera de ...

Page 5: ...ned 16 GND negative supply voltage 17 Positive supply voltage Module top side Digital Output and 1 Wire Bus 18 main supply for digital output 1 2 19 digital output 1 max 8 A 20 digital output 2 max 8 A 21 main supply for digital output 3 4 22 digital output 3 max 8 A 23 digital output 4 max 8 A 24 digital output 5 break contact max 5A 25 main supply for digital output 5 26 digital output 5 make co...

Page 6: ...ser guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11337 V2 0 R1 0 Manual Page 6 of 10 9 Connection Example 1 Wire Gateway sensors and actuators www esera de ...

Page 7: ...ntroller 1 loxone integration 13 Integration in FHEM We provide a software module for easy integration in the Open Source automation software FHEM of the 4 fold analog input into FHEM by 1 Wire Controller 1 Wire Gateway Using this software scripts are no longer necessary Further details can be found on our webpage https www esera de kompatible steuerungen zentralen fhem integration 14 Configuratio...

Page 8: ... and SET commands The ESERA text protocol is totally open and documented The latest version of the ESERA protocol description is available for download in our webshop https www esera de produkte software downloads firmware 1 wire controller 1 wire gateway as well as in the ESERA Config Tool 3 download area 16 2 Modbus TCP protocol 1 Wire Gateway 20 Modbus communication to ESERA text protocol or Mo...

Page 9: ... sure that the unit is disconnected from the mains Components modules or devices may only be put into service if they are mounted in a contact proof housing During installation they must not have power applied Tools may only be used on devices components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside t...

Page 10: ...ade under the Product Liability Act are not affected If defects occur for which the ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical o...

Reviews: