Technical Data
3.3 CAN Interface
Number of CAN
interfaces
1,
optional 2 CAN interfaces
CAN controller
SJA1000
CAN protocol
Basic CAN 2.0A ISO 11898-1
Physical Layer
physical layer according to ISO 11898-2, transmission rate is
programmable from 10 kbit/s to 1 Mbit/s
Bus termination
terminating resistor has to be set externally
Electrical separation of
CAN interfaces from
other units and from
each other
separation by means of optocouplers and DC/DC-converters
DeviceNet-Option
adapter board with DeviceNet connector in Phoenix Combicon style,
optocouplers and CAN driver according to DeviceNet specification
'DeviceNet Communication Model and Protocol, Rel. 2.0'
Table 3:
Data of the CAN interface
3.4 Software Support
Software drivers are available for Windows
®
and Linux
®
. Drivers for other operating systems are
available as well. For detailed information about the driver availability of your special operating
system, please see chapter '8. Order Information' at page 24 or contact our sales team:
Page 10 of 23
Hardware Manual • Doc. No.: C.2021.21 / Rev. 1.1
CAN-PCI/200