The CAN-interface, compatible to ISO11898, allows a data transfer rate of up to 1 Mbit/s. Like many
other properties of the CAN-interfaces, the bit rate can be configured by means of software. The CAN-
interface is electrically insulated from other voltage potentials.
In standard option the module has also got an RS-232 interface, an add-on slot by means of which the
68360 controller ports for three further serial interfaces or an Ethernet interface can be connected, as
well as a multiplex-bus interface for the option to connect peripheral units in the future.