5. TIMER WORK MODE.

F17=1 Delayed switch off

Timer turns on Output1 for T1 time after the START 
command. After that time, timer turns off Output1 and turns 
on beeper. The beeper operates fot the time set in 
F83 parameter. You can mute it with any button in any time. 

Time T1

Output1

On

Off

Time

Time
F83

Beeper

On

Off

START

Time

F17=2 Delayed switch on

Timer counts down T1 time after the START command. After 
that time, timer turns on Output1 and beeper. Beeper 
operates for the time set in F83 parameter. You can mute it 
with any button in any time. 

time T1

Output1

On

Off

Time

Time
F83

Beeper

On

Off

START

Time

F17=3 Cyclic switch off

Timer turns on Output1 for T1 time after the START 
command.after that time, timer turns off Output1for T2 time. . 
Then it switches Output1 on for T1 time again. Cyclic 
operation continues until the RESET command. 

Time T1

Output1

On

Off

Time

Beeper

On

Off

START

Time

Time T2

Time T1

F17=5 Delayed temporary switch on  T1

Timer counts down T2 time after the START command. After 
tha time, timer turns on Output1 for T1 time and then the 
beeper. Beeper operates for the time set in F83 parameter. 
You can mute it with any button in any time. 

czas T1

Output1

On

Off

Time

Beeper

On

Off

START

Time

czas T2

Time
F83

F17=6 Delayed temporary switch on T2

Timer counts down T1 time after the START command. After 
tha time, timer turns on Output1 for T2 time and then the 
beeper. Beeper operates for the time set in F83 parameter. 
You can mute it with any button in any time. 

Time T1

Output1

On

Off

Time

Beeper

On

Off

START

Time

Time T2

Time
F83

F17=4 Cyclic switch on  

Timer counts down T1 time after the START command. After 
that time, timer turns of Output1 for T2 time. Then it turns off 
Output1 for T1 time. Cyclic operation continues until the 
RESET command.

Time T1

Output1

On

Off

Time

Beeper

On

Off

START

Time T2

Time T1

Time

Timer operates in one of the following work modes. Depending on you needs, choose the 
suitable function for your system.
Currently measured time T1 (     icon) or time T2 (     icon) is indicated on the display while 
working . Time T2 is locked, when it is not in use (parameter F17=1,2). After lapse of set time, 
Output1 is turned on or off, which is signalled by       diode. The end of countdown is signalled by 
             message on the display and it can be also signalled by built-in beeper (F83 parameter).

5

Summary of Contents for TC-11

Page 1: ...TC 11 MULTIFUNCTIONAL TIME RELAY TIMER 1 0 version ...

Page 2: ... conditions 5 60 C 0 85 RH non condensing Storage conditions 40 85 C 0 85 RH non condensing Power supply D1 triggering START STOP PAUSE commands D2 triggering RESET command Measuring time accuracy 0 1 Display and time unit setting method User selectable minutes seconds resolution 1 second hours minutes resolution 1 minute Work mode Time relay or time counter 6 user selectable operating modes with ...

Page 3: ...Using or set the minutes value and confirm with button Diodes go off start stop 4 2 TIME SETTING T2 only when the user chooses the operation mode with using two times T1 and T2 parameter F17 3 4 5 6 Hold button for 2 seconds Using or button Set the seconds value and confirm with key Then the minutes rate starts to flash Information To improve quick increasing or decreasing the settings values hold...

Page 4: ... Units Default Description F10 0 Unit and time range selection 0 minutes seconds range 00 01 99min 59s 1 hours minutes range 00 01 99h 59min F11 min s h min 01 00 Time setting T1 value Range 0 1 00 01 99 59 Group Operation parameters F12 min s h min 00 30 Time setting T2 value 00 01 99 59 1 F18 PAUSE function 0 inactive 1 active 0 1 F50 0 Digital input work mode see 6 2 F80 OFF Password to access ...

Page 5: ... the beeper Beeper operates for the time set in F83 parameter You can mute it with any button in any time czas T1 Output1 On Off Time Beeper On Off START Time czas T2 Time F83 F17 6 Delayed temporary switch on T2 Timer counts down T1 time after the START command After tha time timer turns on Output1 for T2 time and then the beeper Beeper operates for the time set in F83 parameter You can mute it w...

Page 6: ... With simple bipolar bistable or bell pulse monostable switch and choose one of the following digital input work modes in F50 parameter Shorting 4 5 contacts circuit the following commands will be triggered F50 1 START command only signal from bipolar or pulse switch Time Input D1 Closed Opened START Time Time count T1 8 0 1 2 3 4 5 6 7 T1 8 Time Input D1 Closed Opened Time Time count 0 1 2 3 4 5 ...

Page 7: ...ce 10 WIRING DIAGRAM Power supply D1 digital input START STOP PAUSE D2 digital input RESET OUT1 output 20A AC1 8A AC3 250V 6 3 EXTERNAL ALARM CONTROL RESET Reset command can be induced by a short circuit signal applied to D2 digital input The 2 3 contacts must be connected to the shorting pulse circuit element including the bell pulse switch monostable Short circuit of 2 3 contacts will induce RES...

Page 8: ...ters display Then release the buttons and the controller restores factory settings and goes into normal operation mode M set 8 Timer meets the requirements for immunity to electromagnetic interference in an industrial environment according to the following standards Electromagnetic compatibility EMC EN 61000 part 6 4 requirements for emissivity in an industrial environment EN 61000 part 6 2 requir...

Reviews: