5. TIMER WORK MODE.
F17=1 Delayed switch off
Timer turns on Output1 for T1 time after the START
command. After that time, timer turns off Output1 and turns
on beeper. The beeper operates fot the time set in
F83 parameter. You can mute it with any button in any time.
Time T1
Output1
On
Off
Time
Time
F83
Beeper
On
Off
START
Time
F17=2 Delayed switch on
Timer counts down T1 time after the START command. After
that time, timer turns on Output1 and beeper. Beeper
operates for the time set in F83 parameter. You can mute it
with any button in any time.
time T1
Output1
On
Off
Time
Time
F83
Beeper
On
Off
START
Time
F17=3 Cyclic switch off
Timer turns on Output1 for T1 time after the START
command.after that time, timer turns off Output1for T2 time. .
Then it switches Output1 on for T1 time again. Cyclic
operation continues until the RESET command.
Time T1
Output1
On
Off
Time
Beeper
On
Off
START
Time
Time T2
Time T1
F17=5 Delayed temporary switch on T1
Timer counts down T2 time after the START command. After
tha time, timer turns on Output1 for T1 time and then the
beeper. Beeper operates for the time set in F83 parameter.
You can mute it with any button in any time.
czas T1
Output1
On
Off
Time
Beeper
On
Off
START
Time
czas T2
Time
F83
F17=6 Delayed temporary switch on T2
Timer counts down T1 time after the START command. After
tha time, timer turns on Output1 for T2 time and then the
beeper. Beeper operates for the time set in F83 parameter.
You can mute it with any button in any time.
Time T1
Output1
On
Off
Time
Beeper
On
Off
START
Time
Time T2
Time
F83
F17=4 Cyclic switch on
Timer counts down T1 time after the START command. After
that time, timer turns of Output1 for T2 time. Then it turns off
Output1 for T1 time. Cyclic operation continues until the
RESET command.
Time T1
Output1
On
Off
Time
Beeper
On
Off
START
Time T2
Time T1
Time
Timer operates in one of the following work modes. Depending on you needs, choose the
suitable function for your system.
Currently measured time T1 ( icon) or time T2 ( icon) is indicated on the display while
working . Time T2 is locked, when it is not in use (parameter F17=1,2). After lapse of set time,
Output1 is turned on or off, which is signalled by diode. The end of countdown is signalled by
message on the display and it can be also signalled by built-in beeper (F83 parameter).
5