3 TECHNICAL DATA
0463 710 001
- 9 -
© ESAB AB 2020
3
TECHNICAL DATA
Technical data
Rogue ES 200i Pro
Rogue ES 180i Pro
Outlet voltage
230 V±15%
1~ 50/60 Hz
115 V±15%
1~ 50/60 Hz
230 V±15%
1~ 50/60 Hz
115 V±15%
1~ 50/60 Hz
Primary current
I
max
MMA
30 A
29 A
26 A
29 A
I
max
Live TIG
19.5 A
24 A
16.5 A
24 A
No-load power
demand when in
energy saving mode 50 W
50 W
50 W
50 W
Setting range
MMA
20-200 A
20-110 A
20-180 A
20-110 A
Live TIG
10-200 A
10-140 A
10-180 A
10-140 A
Permissible load
at MMA
25% duty cycle
200 A / 28 V
110 A / 24.4 V
180 A / 27.2 V
110 A / 24.4 V
60% duty cycle
129 A / 25.2 V
70 A / 22.8 V
116 A / 24.6 V
70 A / 22.8 V
100% duty cycle
100 A / 24 V
55 A / 22.2 V
90 A / 23.6 V
55 A / 22.2 V
Permissible load at
Live TIG
25% duty cycle
200 A / 18 V
140 A / 15.6 V
180 A / 17.2 V
140 A / 15.6 V
60% duty cycle
129 A / 15.2 V
90 A /
13.6 V
116 A / 14.6 V
90 A / 13.6 V
100% duty cycle
100 A / 14 V
70 A /
12.8 V
90 A / 13.6 V
70 A / 12.8 V
Apparent power I
2
at maximum current 6.9 kVA
3.3 kVA
6 kVA
3.3 kVA
Active
power I
2
at maximum current 6.8 kW
3.26 kW
5.94 kW
3.26 kW
Power factor
at maximum current
Live TIG
0.99
0.99
0.99
0.99
MMA
0.99
0.99
0.99
0.99
Efficiency
at maximum current
MMA
82%
82%
82%
82%
Live TIG
82%
82%
82%
82%
Open-circuit voltage U
0
max
VRD 35 V
deactivated
78 V DC
78 V DC
78 V DC
78 V DC
VRD 35 V activated <30 V
<30 V
<30 V
<30 V