4 INSTALLATION
0463 710 001
- 12 -
© ESAB AB 2020
4.3
Mains supply
NOTE!
Rogue ES 180i Pro and ES 200i Pro
comply with IEC 61000-3-12 provided that the
short-circuit power is greater than or equal to S
scmin
at the interface point between the
user's supply and the public system. It is the responsibility of the installer or user of
the equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with a short-circuit power
greater than or equal to S
scmin
. Refer to the technical data in the TECHNICAL DATA
chapter.
The power source will automatically adjust to the supplied input voltage. Make sure that it is
protected by the correct fuse rating. A protective ground connection must be made, in
accordance with regulations.
1.
Rating plate with supply connection
data.
Recommended fuse sizes and minimum cable area for the ES 180i Pro, ES 200i Pro
Supply voltage
230 VAC
115 VAC
Electrical cable area
2.5 mm
2
2.5 mm
2
Maximal current rating
I
max
MMA/Stick (SMAW)
30 A
29 A