28
10 SEC
ENERGIZE
PREFLOW
Postflow
2 SEC.
PUSH RELEASE
PUSH
RELEASE
TORCH SWITCH
OPEN
CLOSE
GAS SOLENOID VALVE
CLOSE
OPEN
FLOW SWITCH
FAULT PILOT LIGHT
HF CIRCUIT
INVERTER
CUTTING ARC (CURRENT)
notes:
1.
When the torch switch is pushed during postflow period, the postflow and preflow times are canceled, and the HF is
energized immediately.
2.
When the amber fault pilot light comes on, cutting operation should be stopped. The postflow time starts from the
moment the torch switch is released.
3.
FAULT pilot light is on during second "turn-off" trigger only. This does not affect performance in any way.
B.
locK-in "on" position