23
Depress torch switch. After 2 seconds, is high frequency present?
No
Repair/replace
high frequency
unit
Repair power
source
Yes
5.3 trouBleshooting guiDe
a. Difficult starting.
• Change electrode
• Change nozzle
• Check for good, clean connection of work lead to workpiece
• Check air pressure (65 - 75 psig)
• Check torch power cable for continuity
B. no air
Is air hose connected?
Yes
No
Connect
Is air adjusted to 65 - 75 psig?
Yes
No
Adjust
Does air come on with air check switch?
Yes
No
• No electrode in torch
• No valve pin in torch
• Replace electrode
Check continuity of torch switch
• Replace valve pin
OK
No
Replace torch switch
Repair power source
figure 5-2. sequence of operations
section 5
maintenance
Summary of Contents for Powercut 650
Page 4: ...4 table of contents...
Page 14: ...14 section 3 installation...
Page 20: ...20 section 4 operation...
Page 32: ...32 section 6 replacement parts...
Page 33: ...33 section 6 replacement parts...
Page 34: ...34 section 6 replacement parts...
Page 35: ...35 section 6 replacement parts...
Page 36: ...36 section 6 replacement parts...
Page 37: ...37 section 6 replacement parts...
Page 38: ...Q1 section 6 replacement parts...
Page 39: ...39 section 6 replacement parts...
Page 40: ...40 section 6 replacement parts...
Page 41: ...41 section 6 replacement parts...
Page 42: ...42 notes...
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......