21
SECTION 3
OPERATION
3.3 CUTTING WITH THE POWERCUT-1250 / 1500
Use the following procedures to cut with the PT-32EH torch.
A.
Make sure that the wall disconnect switch is on. Turn on the Front
Panel Power Switch.
B.
Set Pressure Regulator to 80 psig.
C.
Hold the torch nozzle approximately 1/8 to 3/16 inch above the work and
tilted at about 15 - 30°. This reduces the chance of spatter entering the
nozzle. If the PT-32EH's standoff guide (P/N 0558002393) is being
used, the distance between Electrode and Work Piece will be approx.
3/16-inch.
D.
Depress the torch switch. Air should flow from the torch nozzle.
E.
Two seconds after depressing the torch switch, the pilot arc should
start. The main arc should immediately follow, allowing the cut to begin.
(If using the trigger LOCK mode, torch switch may be released after
establishing the cutting arc.)
F.
After starting the cut, the torch should be maintained at a 5-15° forward
angle (Figure 3-2). This angle is especially useful in helping to create
a "drop" cut. When not using the standoff guide, the nozzle should be
held approximately 1/4 inch from the work.
CUT
DIRECTION
Figure 3-2. Recommended Torch Angle of 5° to 15°
IMPORTANT!!!
Maintain Proper
Stand-Off Distance
3/16 to 1/4 Inch
Power Output increases with Stand Off Distance!
Standoff vs. Power Output
ELECTRIC SHOCK can kill.
• Do NOT operate the unit with the
cover removed.
• Do NOT apply power to the unit
while holding or carrying the unit.
• Do NOT touch any torch parts
forward of the torch handle (nozzle,
heat shield, electrode, etc.) with
power switch on.
ARC RAYS can burn eyes and skin;
NOISE can damage hearing.
• Wear welding helmet with No. 6 or 7
lens shade.
• Wear eye, ear, and body protection.
Position the PowerCut at least 10 feet
(3 meters) from the cutting area. Sparks
and hot slag from the cutting operation
can damage the unit.
Summary of Contents for POWERCUT-1250
Page 1: ...POWERCUT 1250 1500 PLASMARC CUTTING PACKAGE 0558004106 Instruction Manual ...
Page 4: ...4 TABLE OF CONTENTS ...
Page 18: ...18 SECTION 2 INSTALLATION ...
Page 26: ...26 SECTION 3 OPERATION ...
Page 30: ...30 SECTION 4 MAINTENANCE ...
Page 39: ...39 Powercut 1250 1500 Schematic Diagram D 0558003510 A ...
Page 40: ...40 SECTION 5 TROUBLESHOOTING ...
Page 47: ...47 ...