3 TECHNICAL DATA
0349 301 124
- 8 -
© ESAB AB 2017
3
TECHNICAL DATA
Mig L305
Mig L405
Mig L405
Voltage
400-415 V,
3~ 50/60 Hz
400-415 V,
3~ 50/60 Hz
230/400-415/500 V
3~ 50 Hz
230/440-460 V
3~ 60Hz
Permissible load
at 100% duty cycle
150 A
280 A/28 V
280 A/28 V
at 60% duty cycle
190 A
365 A/32 V
365 A/32 V
at 50% duty cycle
-
400 A/34 V
400 A/34 V
at 25% duty cycle
300 A
-
-
Setting range (DC)
30 A/15 V -
300 A/29 V
50 A/16,5 V -
400 A/34 V
50 A/16,5 V -
400 A/34 V
Open circuit voltage
17-40 V
17-45 V
17-45 V
Open circuit power
190 W
360 W
360 W
with cooling unit
-
600 W
600 W
Efficiency at max
current
69%
71%
71%
Power factor at max
current
0,97
0,98
0,98
Control voltage
42 V, 50/60 Hz
42 V, 50/60 Hz
42 V, 50/60 Hz
Dimensions lxwxh
782 x 425 x 830
812 x 552 x 925
812 x 552 x 925
Weight
89 kg
142 kg
143 kg
with cooling unit
-
156 kg
156 kg
Operating
temperature
-10 to +40 °C
-10 to +40 °C
-10 to +40 °C
Transportation
temperature
-20 to +55 °C
-20 to +55 °C
-20 to +55 °C
Enclosure class
IP 23
IP 23
IP 23
Application class
Coolant
ESAB ready mixed coolant
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading. The duty cycle is valid for 40 °C / 104 °F, or below.
Enclosure class
The
IP
code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked
IP23
is intended for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
Summary of Contents for Origo Mig L305
Page 2: ......
Page 11: ...4 INSTALLATION 0349 301 124 11 ESAB AB 2017 4 4 Electrical installation ...
Page 20: ...CLEANING 0349 301 124 20 ESAB AB 2017 CLEANING ...
Page 21: ...DIAGRAM 0349 301 124 21 ESAB AB 2017 DIAGRAM OrigoTM Mig L305 400 415 V ...
Page 22: ...DIAGRAM 0349 301 124 22 ESAB AB 2017 OrigoTM Mig L405 400 415 V ...
Page 23: ...DIAGRAM 0349 301 124 23 ESAB AB 2017 OrigoTM Mig L405 230 500 V ...