4 INSTALLATION
0349 301 124
- 12 -
© ESAB AB 2017
L405
4.5
Mains power supply
Check that the unit is connected to the correct mains power supply voltage, and that it is
protected by the correct fuse size. A protective earth connection must be made, in
accordance with regulations.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable areas
L305
3~ 50/60 Hz
Voltage V
400/415
Current A
at 100% duty cycle
7
at 60% duty cycle
10
at 25% duty cycle
18
Cable area mm
2
4 x 2.5
Fuse, slow A
16
L405
3~ 50 Hz
3~ 50/60 Hz 3~ 50 Hz
3~ 60 Hz
3~ 60 Hz
Voltage V
203
400/415
500
230
440/460
Current A