5 OPERATION
0349 301 124
- 14 -
© ESAB AB 2017
5
OPERATION
General safety regulations for handling the equipment can be found in the "SAFETY"
chapter of this manual. Read it through before you start using the equipment!
WARNING!
Secure the equipment - particularly if
the ground is uneven or sloping.
5.1
Connection and control devices
1
Mains supply switch
8 Connection for return cable (-), high
inductance
2
Main supply switch for cooling unit
9 Connection for return cable (-), low
inductance
3
Switch, precise control
10 Connection for welding current cable (+)
4
Switch, coarse control
11 Connection for control cable for wire
feeder
5
Indicating lamp, power supply ON
12 Connection RED for cooling water from
the wire feed unit
6
Orange indicating lamp, overheating
13 Connection BLUE for cooling water to the
wire feed unit
7
Digital instrument V/A*
NOTE!
*Digital instrument V/A only available on certain models.
Summary of Contents for Origo Mig L305
Page 2: ......
Page 11: ...4 INSTALLATION 0349 301 124 11 ESAB AB 2017 4 4 Electrical installation ...
Page 20: ...CLEANING 0349 301 124 20 ESAB AB 2017 CLEANING ...
Page 21: ...DIAGRAM 0349 301 124 21 ESAB AB 2017 DIAGRAM OrigoTM Mig L305 400 415 V ...
Page 22: ...DIAGRAM 0349 301 124 22 ESAB AB 2017 OrigoTM Mig L405 400 415 V ...
Page 23: ...DIAGRAM 0349 301 124 23 ESAB AB 2017 OrigoTM Mig L405 230 500 V ...