Edition 071024
-- 26 --
smlhfpw2
INSTALLATION
The installation must be executed by a professional.
WARNING!
This product is intended for industrial use. In a domestic environment this product may cause radio
interference. It is the user’s responsibility to take adequate precautions.
The power supply should be lifted by means of its lifting
eye. The handle is only intended for pulling it along the
ground.
Lifting instructions
S
Check that the welding rectifier is configured for the
available mains supply
before connecting it to the mains.
S
See Connecting to mains for cable rating and fuse rating.
S
Connect the mains cable to the rectifier according to the relevant regulations and
install a suitable fuse in the main fuse box.
S
Make sure the welding rectifier is not covered or positioned so that cooling is
obstructed.
Connecting to mains
LHF 405 PIPEWELD
LHF 615 PIPEWELD
Frequency
50 Hz
50 Hz
Voltage
230/400/415/500 V
230/400/415/500 V
Current at
100% duty cycle
44/25/25/20 A
59/34/34/27 A
60% duty cycle
56/32/32/26 A
78/45/45/36 A
35% duty cycle
71/41/41/33 A
103/59/59/47 A
Fuse
, slow
63/35/35/25 A
80/63/63/50 A
Cable area
(4xmm2)
10/6/6/4
25/10/10/10
LHF 405 PIPEWELD
LHF 615 PIPEWELD
Frequency
60 Hz
60 Hz
Voltage
230/440/550V
230/440/550V
Current at
100% duty cycle
44/23/18 A
59/31/25 A
60% duty cycle
56/29/23 A
78/41/33 A
35% duty cycle
71/37/30 A
103/54/43 A
Fuse
, slow
63/35/25 A
80/63/50 A
Cable area
(4xmm2)
10/6/4
25/10/10
Summary of Contents for LHF 405 PIPEWELD
Page 7: ...Edition 071024 7 smlhfpw1 LHF 405 PIPEWELD...
Page 10: ...Edition 071024 10 smlhfpw1 LHF 615 PIPEWELD...
Page 19: ...Edition 071024 19 smlhfpw1 LH20 1 Components layout...
Page 20: ...Edition 071024 20 smlhfpw1 LH10 2 Components layout...
Page 28: ...Edition 071024 28 smlhfpw2 Assembly of components...
Page 32: ...32 notes NOTES...
Page 33: ...33 notes...