smlhfpw1
Thermal switch (thermostat) replacement procedure
1.
Spare thermostat must be the same type as replaced one.
2.
Spare thermostat should be mounted within radius of 10mm or less from broken
thermostat. If it’s possible and safe for transformer winding, broken thermostat may be
removed. Then the spare thermostat is to be mounted right in place of broken one.
3.
Spare thermostat should adjoin protected winding as tight as possible.
4.
Spare thermostat must be secured with silicone glue of working temperature of 200
o
C
or higher.