DESCRIPTION OF OPERATION
LH20/1 control board
LH20/1:1 Current setting
The bandgap reference 1,23V diode V2 on LH10/2 PCB makes up a primary
voltage reference for current setting circuit and for digital meter. Current setting
reference voltage 10,7V is derived from 1,23V by the amplifier made of A2a, V30,
C14, R47, R46. The 10,7V voltage establishes reference for local current setting
potentiometer R01 as well as remote control circuitry (X02 socket).