ASSEMBLY PROCEDURES 8-4 Manual 0-5449
8.03 Installing Front Panel
1. Reinstall output terminals on front panel with 27mm wrench.
2. Place front panel PCB assembly into front panel and install screws.
A-12936
3. Reconnect torch polarity cable to the torch connector.
4. Reconnect positive output terminal bolts and tighten with 17mm wrench. ( Note: reconnect wires, pay attention to the wire color.)
5. Reconnect negative output terminal bolts and tighten with 17mm wrench. (Note: reconnect wires and pay attention to the wire
color.)
6. Reconnect the red two wired plug into the PCB as shown in the photo on the following page.