ESAB FABRICATOR 181i
Manual 0-5449 6-7 TROUBLESHOOTING
6.09 Check Main On / Off Switch
23
24
25
26
Art # A-10459
Power Switch Testing
Multimeter Lead Placement
Impedance
Switch ON
Positive meter lead to testpoint 23
Negative meter lead to testpoint 24
0 to 1 Ω
Switch ON
Positive meter lead to testpoint 25
Negative meter lead to testpoint 26
0 to 1 Ω
Switch OFF
Positive meter lead to testpoint 23
Negative meter lead to testpoint 24
> 1k Ω
Switch OFF
Positive meter lead to testpoint 25
Negative meter lead to testpoint 26
> 1k Ω
Table 6-7 Power Switch, Multimeter set to measure ohms (Ω)
6.10 Check Main Input Rectifier
Input Rectifier Testing
Multimeter Lead Placement
Diode Voltage
AC1 to DC+
Positive meter lead to AC1
Negative meter lead to testpoint DC+
0.2 – 0.8 VDC
AC2 to DC+
Positive meter lead to AC2
Negative meter lead to testpoint DC+
0.2 – 0.8 VDC
AC1 to DC-
Positive meter lead to testpoint DC-
Negative meter lead to testpoint AC1
0.2 – 0.8 VDC
AC2 to DC-
Positive meter lead to testpoint DC-
Negative meter lead to testpoint AC2
0.2 – 0.8 VDC
Table 6-8 IGBT’s, Multimeter set to measure Diode Voltage
Measurements may be made directly onto the main input rectifier. AC1 and AC2 may be measured from the pins on the mains supply
plug with the main power switch set to the ON position.
Summary of Contents for Fabricator 181i
Page 18: ...ESAB FABRICATOR 181i SAFETY AND INSTALLATION 3 8 Manual 0 5449 This Page Intentionally Blank...
Page 40: ...ESAB FABRICATOR 181i THEORY OF OPERATION 5 2 Manual 0 5449 This Page Intentionally Blank...
Page 64: ...ESAB FABRICATOR 181i DISASSEMBLY PROCEDURES 7 4 Manual 0 5449 A 09965_AB...
Page 71: ...ESAB FABRICATOR 181i Manual 0 5449 8 3 ASSEMBLY PROCEDURES 8 7 A 10011 9 A 10114...
Page 73: ...ESAB FABRICATOR 181i Manual 0 5449 8 5 ASSEMBLY PROCEDURES A 09965_AB...
Page 76: ...ESAB FABRICATOR 181i ASSEMBLY PROCEDURES 8 8 Manual 0 5449 This Page Intentionally Blank...
Page 82: ...REVISION HISTORY Date Rev Description 09 18 2015 AA Manual release...
Page 83: ......