ESAB FABRICATOR 141i
Manual 0-5448 6-7 TROUBLESHOOTING
IGBT Testing
Multimeter Lead Placement
Impedance
IGBT 1
Positive meter lead to testpoint 17
Negative meter lead to testpoint 9
150 to 350 Ω
IGBT 2
Positive meter lead to testpoint 18
Negative meter lead to testpoint 11
150 to 350 Ω
IGBT 4
Positive meter lead to testpoint 19
Negative meter lead to testpoint 13
150 to 350 Ω
IGBT 5
Positive meter lead to testpoint 20
Negative meter lead to testpoint 15
150 to 350 Ω
Table 6-4 IGBT’s, Multimeter set to measure ohms (Ω)
Inrush PTC
Multimeter Lead Placement
Impedance
PTC
Positive meter lead to testpoint 21
Negative meter lead to testpoint 22
80 to 120 Ω
Table 6-5 Inrush PTC, Multimeter set to measure ohms (Ω)
6.08 Check Main ON / OFF Switch
23
24
25
26
Art # A-10459
Power Switch Testing
Multimeter Lead Placement
Impedance
Switch ON
Positive meter lead to testpoint 23
Negative meter lead to testpoint 24
0 to 1 Ω
Switch ON
Positive meter lead to testpoint 25
Negative meter lead to testpoint 26
0 to 1 Ω
Switch OFF
Positive meter lead to testpoint 23
Negative meter lead to testpoint 24
> 1k Ω
Switch OFF
Positive meter lead to testpoint 25
Negative meter lead to testpoint 26
> 1k Ω
Table 6-6 Power Switch, Multimeter set to measure ohms (Ω)
Summary of Contents for fabricator 141i
Page 19: ...ESAB FABRICATOR 141i Manual 0 5448 3 9 SAFETY AND INSTALLATION Notes...
Page 20: ...ESAB FABRICATOR 141i SAFETY AND INSTALLATION 3 10 Manual 0 5448 This Page Intentionallly Blank...
Page 40: ...ESAB FABRICATOR 141i OPERATION 4 20 Manual 0 5448 This Page Intentionally Blank...
Page 42: ...ESAB FABRICATOR 141i THEORY OF OPERATION 5 2 Manual 0 5448 Notes...
Page 70: ...ESAB FABRICATOR 141i DISASSEMBLY PROCEDURE 7 4 Manual 0 5448 2 3 4 Art A 12181...
Page 81: ...ESAB FABRICATOR 141i Manual 0 5448 8 7 ASSEMBLY PROCEDURES Notes...
Page 82: ...ESAB FABRICATOR 141i ASSEMBLY PROCEDURES 8 8 Manual 0 5448 Notes...
Page 88: ...ESAB FABRICATOR 141i KEY SPARE PARTS 9 6 Manual 0 5448 Notes...
Page 91: ......