ESAB FABRICATOR 141i
Manual 0-5448 6-5 TROUBLESHOOTING
6.05 Clear protective Sheet Removal
!
WARNING
Read and follow safety information in Section 6.02 before proceeding.
1. Clear protective sheet
Take out clear protective sheet.
1
Art # A-12170
6.06 Visually Inspect
Visually inspect the inside of the Power Source. The levels of current present in these units can cause burning or arcing of PCB, trans-
formers, switches, or rectifier when a failure occurs. Carefully inspect all components within these units.
Look in particular for the following:
a) Loose or broken wires or connectors.
b) Burned or scorched parts or wires or evidence of arcing.
c) Any accumulation of metal dust or filings that may have caused shorting or arcing.
If any parts are damaged, they must be replaced. Refer to the Spare Parts section for a complete list of components used in the Power
Source.
Locate the faulty component(s) then replace where necessary.
Summary of Contents for fabricator 141i
Page 19: ...ESAB FABRICATOR 141i Manual 0 5448 3 9 SAFETY AND INSTALLATION Notes...
Page 20: ...ESAB FABRICATOR 141i SAFETY AND INSTALLATION 3 10 Manual 0 5448 This Page Intentionallly Blank...
Page 40: ...ESAB FABRICATOR 141i OPERATION 4 20 Manual 0 5448 This Page Intentionally Blank...
Page 42: ...ESAB FABRICATOR 141i THEORY OF OPERATION 5 2 Manual 0 5448 Notes...
Page 70: ...ESAB FABRICATOR 141i DISASSEMBLY PROCEDURE 7 4 Manual 0 5448 2 3 4 Art A 12181...
Page 81: ...ESAB FABRICATOR 141i Manual 0 5448 8 7 ASSEMBLY PROCEDURES Notes...
Page 82: ...ESAB FABRICATOR 141i ASSEMBLY PROCEDURES 8 8 Manual 0 5448 Notes...
Page 88: ...ESAB FABRICATOR 141i KEY SPARE PARTS 9 6 Manual 0 5448 Notes...
Page 91: ......