![ESAB ET 220i AC/DC Operating Manual Download Page 39](http://html1.mh-extra.com/html/esab/et-220i-ac-dc/et-220i-ac-dc_operating-manual_2424782039.webp)
ET 220I AC/DC
Manual 0-5346
INSTALLATION, OPERATION AND SETUP
3-27
Menu item
Range
LED Code
(Left Display)
Parameter Value
(Right Display)
Factory
Setting
C08 – Foot Control Minimum
Current (GTAW AC mode only)
When set to “ON” the increased
Foot Control Minimum current
is disabled and the minimum
current on any electrode is 5A.
When set to “OFF” the increased
Foot Control Minimum current
is enabled.
The minimum currents are:
electrode 0.040" – 0.080" (10A)
electrode 3/32" (15A)
electrode 1/8" (20A)
ON
OFF
OFF
C09
(SMAW mode only)
Set to “OFF”.
OFF
OFF
Table 3-10: User Specific Menus
3.17 Special Function
Soft Reset
• Press and hold the BACK button (22).
• Press the SAVE button (53).
• All control panel LED’s will light up briefly to confirm the Soft Reset has been completed.
NOTE!
The only difference between soft & hard reset is that on a hard reset, presets or jobs will be erased. On a
soft reset they will remain.
Art # A-12852
T
4T
2T
Figure 3-15: Soft Reset