6 CONTROL PANEL
0463 416 001
- 25 -
© ESAB AB 2017
6.3
TIG settings
Symbol
Function
Setting range Setting steps
Default
value
ET 300i ET 300iP
TIG HF*
ON/OFF
ON
X
X
LiftArc*
ON/OFF
OFF
X
X
Current
1ph: 5–200 A
3ph: 5–300 A
1
100 A
X
X
Slope up time H: 0.0–9.9 s
0.0–25.0 s
0.1
1.5 s
H
X
Slope down
time
0.0–25.0 s
0.1
3.0 s
X
X
Gas pre flow
time
H: 0.0–9.9 s
0.0–25.0 s
0.1
1.0 s
H
X
Gas post flow
time
0.0–25.0 s
0.1
7.0 s
X
X
2-stroke*
ON/OFF
ON
X
X
4-stroke*
ON/OFF
OFF
X
X
Remote
control unit*
ON/OFF
OFF
X
X
Pulse*
ON/OFF
OFF
X
Pulse current 1ph: 5–200 A
3ph: 5–300 A
120 A
X
Background
current
1ph: 5–200 A
3ph: 5–300 A
80 A
X
Pulse balance 10–90%
5
50%
X
Pulse
frequency
0.01–999 Hz
0.10–0.99: 0.01
1.0–9.9: 0.1
10–100: 1
100–300: 10
300–999: 100
100 Hz
X
Remote min
current
0–99%
1
20%
H
H
*) Parameter cannot be changed while welding
H = Hidden
function
Summary of Contents for ES 300i