6 CONTROL PANEL
0463 416 001
- 21 -
© ESAB AB 2017
6
CONTROL PANEL
6.1
ET 300i
1.
Memory 1, 2 and 3.
8.
Current set and measure value / Voltage
measure value
2.
Display, shows set or measured value.
9.
Slope down indicator.
3.
Button to select welding method: TIG HF,
LiftArc™ or MMA.
10.
Gas post flow indicator.
4.
Set indicator.
11.
Parameter selection button, selection
indicated by (8) to (10). Also used for
access to hidden fuctions.
5.
Button to select 2-stroke or 4-stroke (TIG
only).
12.
Overheating indicator.
6.
Button to activate and deactivate remote
control unit.
13.
VRD function (reduced open-circuit
voltage) indicator.
7.
Knob for setting data.
6.1.1
Navigation
Parameter selection
By pressing the button (11) different values can be shown. Use the knob (7) to change the
values. The sequence is:
1.
Set current value.
2.
Measured current value.
3.
Measured voltage value.
4.
Slope down (TIG only)
5.
Gas post flow (TIG only)
Summary of Contents for ES 300i