S0740 800 191/E080229/P78
-- 39 --
cu19_20_1
Methods of measuring the arc voltage
Various methods of measurement are available by transferring a link between
contacts Y1, Y2 and Y3. When delivered, the link is fitted between Y2 and Y3.
The link must be connected between Y2 and Y3 for MMA and TIG welding.
S
Welding with the filler wire positive: voltage sensing from the wire
.
This is the commonest arrangement for MIG welding.
Y2 -- Y3 must be linked. This method of measurement allows for the
voltage drop in the supply conductor (= to the welding gun). The input
signal is measured between inputs X1 and W2. Amplifier IC8:14 is active.
S
Welding with the filler wire negative: voltage sensing from the wire
Y2 -- Y3 must be linked. This method of measurement allows for the
voltage drop in the supply conductor. The input signal is measured
between inputs X1 and W5. Amplifier IC8:8 is active.
S
Welding with the filler wire positive or negative, without external
sensing from the wire or workpiece.
Y2 -- Y3 must be linked. The input signal is measured between inputs W5
and W2 (= the voltage at the power source terminals), as there is no
connection to X1. Amplifier IC8:14 is active.
S
Welding with the filler wire positive: voltage sensing from the wire
and workpiece.
Y1 and Y2 must be linked. This method allows for the voltage drop in both
the supply and return conductors. The input signal is measured between
X1 and X3. Amplifier IC8:14 is active.
Note:
If the voltage signal connection to X3 is lost, the power source loses
control of the arc voltage.
Summary of Contents for Aristo Arc 4000i
Page 14: ...S0740 800 191 E080229 P78 Mig U4000i valid for serial number 803 xxx xxxx 14 cu19_00...
Page 15: ...S0740 800 191 E080229 P78 15 cu19_00...
Page 16: ...S0740 800 191 E080229 P78 Mig 4000i valid for serial number 803 xxx xxxx 16 cu19_00...
Page 17: ...S0740 800 191 E080229 P78 17 cu19_00...
Page 18: ...S0740 800 191 E080229 P78 Tig 4000i valid for serial number 803 xxx xxxx 18 cu19_00...
Page 19: ...S0740 800 191 E080229 P78 19 cu19_00...
Page 20: ...S0740 800 191 E080229 P78 Arc 4000i valid for serial number 803 xxx xxxx 20 cu19_00...
Page 21: ...S0740 800 191 E080229 P78 21 cu19_00...
Page 28: ...S0740 800 191 E080229 P78 28 ct32_15 15AP1 Component positions...
Page 41: ...S0740 800 191 E080229 P78 20AP1 Component positions 41 cu19_20_1...
Page 49: ...S0740 800 191 E080229 P78 49 cu19_20_2 20AP2 Circuit diagram...