2. Connect an oscilloscope to the SST 2 across terminals GND2 and P2, as shown on
page 60.
Test points for gate pulses from 20AP1
3. Compare the waveform of the gate pulses with the diagram below.
The waveform shape must be as in the diagram.
Pulses from 20AP1 to 15AP2 when the output of 20AP1 is connected to 15AP2.
4. Measure the pulse frequency, it must be 27 kHz
±
0.5 kHz.
5. Measure the pulse duration, it must be 41 -- 43 % of the cycle time, measured at --10 V
on the negative pulse, as shown in the diagram above.
6. Measure the maximum pulse voltage, it must be in the range 30 -- 38 V.
The minimum voltage must be in the range from --14 to --16 V.
7. Connect the probe to terminal P1 and the screen to GND1 of the SST 2.
8. Repeat the measurements in item 3 to 6 above.
The pulses on P1 and P2 are in phase with each other.
If the pulse transformer on circuit board 15AP2 is not connected, or if there is a break in the
transformer primary, the pulses will look as shown in the figure below.
Pulses from 20AP1 when the output from 20AP1 is
not
connected to 15AP2.
Summary of Contents for Aristo Arc 4000i
Page 14: ...S0740 800 191 E080229 P78 Mig U4000i valid for serial number 803 xxx xxxx 14 cu19_00...
Page 15: ...S0740 800 191 E080229 P78 15 cu19_00...
Page 16: ...S0740 800 191 E080229 P78 Mig 4000i valid for serial number 803 xxx xxxx 16 cu19_00...
Page 17: ...S0740 800 191 E080229 P78 17 cu19_00...
Page 18: ...S0740 800 191 E080229 P78 Tig 4000i valid for serial number 803 xxx xxxx 18 cu19_00...
Page 19: ...S0740 800 191 E080229 P78 19 cu19_00...
Page 20: ...S0740 800 191 E080229 P78 Arc 4000i valid for serial number 803 xxx xxxx 20 cu19_00...
Page 21: ...S0740 800 191 E080229 P78 21 cu19_00...
Page 28: ...S0740 800 191 E080229 P78 28 ct32_15 15AP1 Component positions...
Page 41: ...S0740 800 191 E080229 P78 20AP1 Component positions 41 cu19_20_1...
Page 49: ...S0740 800 191 E080229 P78 49 cu19_20_2 20AP2 Circuit diagram...