S0740 800 191/E080229/P78
-- 33 --
cu19_20_1
Uan
5 V internal reference voltage on 20AP1.
Uref
2.5 V internal reference voltage on 20AP1.
20AP1:2
Fan control
When the mains power supply is turned on, the fans are off. After about 4
seconds they start and run at full speed, for a short moment, before shutting
down until welding starts.
The fan speed depends on the welding current. For loads up to 146 A, the fans
run at low speed, supplied at about 18 V. At load currents above 146 A, the
fans are supplied at 24 V and run at full speed. On conclusion of welding, the
fans continue to run for 6.5 minutes.
If the welding current is above 146 A and then is recuced to a lower value, the
fans continue to run at full speed for 6.5 minutes, before dropping to the lower
speed.
If overtemperature is detected, the fans run at high speed until the power
source has cooled down to normal temperature.
Summary of Contents for Aristo Arc 4000i
Page 14: ...S0740 800 191 E080229 P78 Mig U4000i valid for serial number 803 xxx xxxx 14 cu19_00...
Page 15: ...S0740 800 191 E080229 P78 15 cu19_00...
Page 16: ...S0740 800 191 E080229 P78 Mig 4000i valid for serial number 803 xxx xxxx 16 cu19_00...
Page 17: ...S0740 800 191 E080229 P78 17 cu19_00...
Page 18: ...S0740 800 191 E080229 P78 Tig 4000i valid for serial number 803 xxx xxxx 18 cu19_00...
Page 19: ...S0740 800 191 E080229 P78 19 cu19_00...
Page 20: ...S0740 800 191 E080229 P78 Arc 4000i valid for serial number 803 xxx xxxx 20 cu19_00...
Page 21: ...S0740 800 191 E080229 P78 21 cu19_00...
Page 28: ...S0740 800 191 E080229 P78 28 ct32_15 15AP1 Component positions...
Page 41: ...S0740 800 191 E080229 P78 20AP1 Component positions 41 cu19_20_1...
Page 49: ...S0740 800 191 E080229 P78 49 cu19_20_2 20AP2 Circuit diagram...