1-8-2
TD900EA
2. H Adjustment
Purpose: To get correct horizontal position and size of
screen image.
Symptom of Misadjustment: Horizontal position and
size of screen image may not be properly displayed.
Note: R583 --- H.V. CBA
1. Connect Frequency Counter to R583.
2. Operate the unit for at least 20 minutes.
3. Enter the Service mode. (See page 1-8-1.) Press
"2" button on the remote control unit and select H-
ADJ Mode.
4. Press CH
o
/
p
buttons on the remote control unit
so that the display will change "0" to "7."
5. At this moment, choose display "0" to "7" when the
Frequency counter display is closest to
15.734kHz
±
300Hz.
6. Turn the power off and on again.
3. C-Trap Adjustment
Purpose: To get minimum leakage of the color signal
carrier.
Symptom of Misadjustment: If C-Trap Adjustment is
incorrect, stripes will appear on the screen.
Note: D1304 (Cathode) (B-Out)--- Main CBA
1. Connect Oscilloscope to D1304 (Cathode).
2. Input a color bar signal from RF input.
Enter the Service mode. (See page 1-8-1.)
3. Press "0" button on the remote control unit and
select C-TRAP Mode.
4. Press CH
o
/
p
buttons on the remote control unit
so that the carrier leakage B-Out (3.58MHz) value
becomes minimum on the oscilloscope.
5. Turn the power off and on again.
Test point
Adj. Point
Mode
Input
R583
CH
o
/
p
buttons
Video
---
Tape
M. EQ.
Spec.
---
Frequency Counter
15.734kHz
±
300Hz
Test point
Adj. Point
Mode
Input
D1304
(Cathode)
(B-OUT)
CH
o
/
p
buttons
---
Color Bar
Tape
M. EQ.
Spec.
---
Oscilloscope
Pattern Generator
---
Figure
minimum
Fig. 2
Summary of Contents for EC720E
Page 2: ...EC720E T1008UJ 2004 06 22 ...
Page 22: ...1 7 4 TD900DC S 4 S 4 S 4 S 4 4 CRT Anode Cap CRT CBA Fig 3 ...
Page 93: ...2 4 8 TD951DA Fig DM16 41 42 43 L 13 44 45 P 9 Slide Fig DM17 ...
Page 97: ...3 1 3 TD900PEX S4 S1 X1 TAPE X5 X4 X2 X3 S3 S6 S7 S2 PACKING TAPE Packing ...
Page 119: ...Printed in Japan 2003 08 25 HO 6720FDD TD900UA ...