5.1 ENTER DATA IN SET MODE
SETUP / DISPLAY
DESCRIPTION
Range
Code Default
00
LANGUAGE SEL.
SL
ENGLISH
Display language selection
SL
01
DIGITAL INPUTS
C0
DISABLE
ENABLE / DISABLE inputs from external contacts
C0
02
OPERATION
C4b
MANUAL
Operation Mode selection AUTOMATIC / MANUAL
C4b
03
PULSE TIME
B2x
0.50 sec.
Pulse time from 0.05 to 5.00 sec.
0.05÷5.00 B2x
0.50 sec.
04
INTERVAL TIME
B3x
005 sec.
Interval time between ev. from 1 to 999 sec.
001÷999
B3x
5 sec.
05
POSTCL INT.
B3c
005 sec.
Interval time between ev. during post-cleaning from 1 to 999 sec.
001÷999
B3c
5 sec.
06
POST CYCLES
D1x
002 cycles
Number additional cycles after fan stop
00÷99
D1x
5
07
ELECTROVAL.N.
B1b
016 ev.
Selection Number of electrovalves
B1b
08
EV TEST
B10
001 OFF
TEST Manual activation of
every single ev. from keyboard
B10
09
HOURS COUNTER
D14a
00000 Hours
Operation hours-counter
0÷65535
D14a
10
ZERO dP ADJ.
C8
0.00 kPa
dP zero readout regulation
C8
0.00
11
FAN THRESHOLD
D1bx
0.10 kPa
dP threshold for cycle activation after fan stop
0.01÷0.99 D1bx
0.10
12
MIN dP ALARM
C7c1
OFF
Minimum dP alarm threshold
0.01÷9.99 C7c1
OFF
13
dP STOP CYCLE
C1a
1.00 kPa
1st dP threshold, STOP cleaning since dP low
0.01÷9.99 C1a
1.00
14
dP START CYCLE
C1d
2.00 kPa
2nd dP threshold, START cleaning since dP high
0.01÷9.99 C1b
2.00