5.1 ENTER DATA IN SET MODE
SETUP / DISPLAY
DESCRIPTION
Range
Code Default
E3
BROKEN BAG
D11
ELECTROVALVE 003
Alarm for broken bag check ev 3
D11
E4
EMISSION TC
D12c
OVER THRESHOLD
Continuous emission of dust above the set threshold
D12c
E5
PROBE SIGNAL
D12c
TRIBO < 2mA
TRIBO CHECK probe signal below 2 mA
D12c
E6
COMPR. AIR
LACK D5a OPEN
Cycle stop since no consent from compressed air pressure switch
D5a
E7
MAXIMUM
dP ALARM
Maximum dP alarm active. dP reading over SET 15 (See section 5.1)
C7d
E8
MINIMUM
dP ALARM
Minimum dP alarm active dP reading under SET 12. (See section 5.1)
C7c