5.1 ENTER DATA IN SET MODE
SETUP / DISPLAY
DESCRIPTION
Range
Code Default
20
TC CONTROL
D11
ON
Inclusion / exclusion TC probe control
D11
21
ZERO TC ADJ.
D17
00 mg/m3
TC reading zero adjustment. (TC reading on display)
-9 ÷ +9
D17
22
TC ADJUST.
D18
20 mA = 100
TC reading adjustment to get value on display in mg/m3
D18
23
ALL. TC DELAY
D12a1 010 sec.
Delay for the activation of the continuos emission alarm
1 ÷ 250
D12
25
TC ALARM THRES.
D12c
050 mg/m3
Continuous emission alarm threshold
1 ÷ 99
D12b1
24
SENSITIVITY
D21
5 = 06 mA
Sensitivity for broken bag check
0 ÷ 9
D21
26
TC MEAN TIME
D19
010 sec.
TC probe signal readout average time
1 ÷ 60
D19
27
mA TC READING
D20
04.0 mA
TC output current in mA
D20
L
TC READING
001 mg/m3
TC reading on display during test for mg/m3 adjustment
Press D and B. See D18
1 ÷ 99
D18
A
REAL EMISSION
001 mg/m3
Real TC emission during test for adjustment in mg/m3
Press D and B. See D18
1 ÷ 99
D18
6.1 DISPLAY INDICATIONS IN OPERATION
DISPLAY
DESCRIPTION
Code
dP = 1.06 kPa MAN
Differential pressure reading (dP = xxx) and manual running mode (MAN)
C3