VULCAN hydraulic actuator
61
INSTALLATION
Long actuator, inward opening
Opening
angle
Dimens
ion A
Dimens
ion B
80º
250
180
85º
235
175
90º
200
195
90º
235
150
95º
220
155
100º
175
190
110º
190
155
i
Use of the chart:
For a specific opening angle, multiple A-B pairs can
be chosen. Generally, one of them will be
determined by the characteristics of the installation
(size of the pillar, presence of walls, etc).
1
Select the specified dimension in the chart.
2
Following the grid, move from the dimension to
the line corresponding to the required opening
angle.
3
Following the grid, move to the other
dimension.