E
N
G
L
IS
H
9
TECHNICAL DATA
INSTALLATION OF THE MOTOR
INSTALLATION LAYOUT
���
CICLÓN actuator
cable 3 x 1 mm
2
���
Control unit
cable 3 x 1,5 mm
2
���
Flashing light with
built-in antenna (LUMOS-M)
cable 2 x 1 mm
2
cable RG174 (antenna)
���
Photocells
cable 4 x 0,5 mm
2
(RX)
cable 2 x 0,5 mm
2
(TX)
���
Key switch
cable 2 x 0,5 mm
2
���
Transmitter
-
���
Pillar photocells
cable 4 x 0,5 mm
2
(RX)
cable 2 x 0,5 mm
2
(TX)
���
Pillar-mounted digital
radio switch
-
Maximum leaf length (m)
2,5
Maximum leaf weight (Kg)
400
Power supply (Vac - Hz)
230 / 50
Current (A)
1
Rated power (W)
230
Capacitor (μF)
5
Speed (Rpm)
1,3
Torque (Nm)
220
Working temperature (°C)
-20 ÷ +60
Protection degree (IP)
54
Working cycle (%)
20
Motor weight (Kg)
13
OPERATING LIMITS
m
Values for orientation purposes. The form of the leaf
and the presence of strong wind may bring notable
differences in the values of the chart.
m
We recommend using an electrolock for leaf
lengths of over 1.8m.
DX