Mantenimiento_113.fm -
14/3/11
30
Installation Manual
MAINTENANCE AND DIAGNOSIS OF FAILURES
1
MAINTENANCE
This operator does not require any special care.
However, it is necessary to carry out the following
checks every 6 months:
Disconnect the device from the power supply
before carrying out any maintenance
operation.
1
Frequently check the facility in order to discover any
imbalance or sign of deterioration or wear. Do not
use the device if any repair or adjustment is
necessary.
2
Clean and lubricate the articulations of the door, so
as not to increase the effort of the operator.
3
Check that the controls and photocells, as well as
their installation, have not suffered any damage
from the weather or external agents.
4
Check unlocking can be carried out easily.
2
FAILURE DIAGNOSIS
3
SCRAP
The operator, up until the end of its useful life,
must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner possible accidents and damage to
adjacent facilities will be avoided.
}
The operator must be deposited in the appropriate
containers for subsequent recycling, separating and
classifying of the different materials in line with their
nature. NEVER deposit it in domestic rubbish or in
landfills which are not suitably controlled, as this will
cause environmental contamination.
Problem
Cause
Solution
The operator does not make any
movement when the key
commands are activated
Absence of system power supply
voltage
Reestablish the power supply
Electrical installation defective
Check that the installation does not
present any short-circuits or cut-off
points
Defective control panel or control
devices
Check these elements, seeing their
respective manuals
The transmitter radio code is not
programmed in the control panel.
Programme the radio code (see the
control panel manual)
Transmitter batteries flat
Replace the batteries
By activating the opening or closing
controls, the operator is enabled
but the door does not move
Door obstructed or blocked
Unblock, adjust and lubricate the door
joints
The door cannot completely close
(or open)
The photocell detects an obstacle
Remove the obstacle and try again
The resistance of the door has
increased when closing (or when
opening)
Check the moving parts of the door
and remove the resistance
The thrust of the operator during
closing (or opening) is too low
Increase the closing or opening thrust
using the control panel programming.
IZ1C / IZ4C / IZ4DC only: The limit
switches of the operator are
maladjusted
Adjust the limit switches
IZS1, IZS4, IZS4D only: travel not
programmed correctly
Correctly programme the open/close
The crankshafts have not been
correctly installed
Remove the crankshafts and mount
them, respecting the indicated levels